AK09912 Datasheet, PDF (34/42 Pages) HuaXinAn Electronics CO.,LTD – 3-axis Electronic Compass | |||
|
◁ |
8.3.7. CNTL1: Control 1
[AK09912]
Addr.
Register
name
D7
D6
D5
D4
D3
D2
D1
D0
Read/Write register
30H CNTL1 TEM NSF1 NSF0
0
0
0
0
0
Reset
0
0
0
0
0
0
0
0
TEM: Temperature measurement setting
â0â: disable
â1â: enable
When TEM bit is â1â, temperature sensor measurement is enabled. Temperature sensor is measured together with magnetic
sensor. Refer to 6.5 for detailed information.
NSF[1:0]: Noise suppression filter setting
â00â: disable
â01â: Low
â10â: Middle
â11â: High
Output data from magnetic sensor is filtered to suppress the noise according to the setting. Refer to 6.6 for detailed
information.
8.3.8. CNTL2: Control 2
Addr.
Register
name
D7
31H CNTL2 0
Reset
0
D6
D5
D4
D3
D2
D1
D0
Read/Write register
0
0
MODE4 MODE3 MODE2 MODE1 MODE0
0
0
0
0
0
0
0
MODE[4:0]: Operation mode setting
â00000â: Power-down mode
â00001â: Single measurement mode
â00010â: Continuous measurement mode 1
â00100â: Continuous measurement mode 2
â00110â: Continuous measurement mode 3
â01000â: Continuous measurement mode 4
â01010â: External trigger measurement mode
â10000â: Self-test mode
â11111â: Fuse ROM access mode
Other code settings are prohibited.
When each mode is set, AK09912 transits to the set mode. Refer to 6.3 for detailed information.
MS1547-E-02
- 34 -
2014/7
|
▷ |