English
Language : 

AT1305 Datasheet, PDF (3/13 Pages) Aimtron Technology – PFM Step-Up DC/DC Converter with LDO
AT1305
Preliminary Product Information
PFM Step-Up DC/DC Converter with LDO
Absolute Maximum Ratings*1
Parameter
Symbol
Power supply voltage
LX pin voltage
OUT output voltage
Other I/O pin voltage
VDD
VLX
VOUT
Condition
—
—
—
—
Rated Value
Min.
Max.
—
6.0
—
6.0
—
6.0
—
6.0
(Ta=+250C)
Unit
V
V
V
V
LX pin output current
ILX
LDO output Peak Current
ILDO
Allowable dissipation
PD
Operating temperature
TOP
Storage temperature
Tstg
—
—
TSSOP8
—
—
—
2
A
—
400
mA
—
500
mW
-30
+85
0C
-55
+165
0C
1. Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the
device. These are stress ratings only, and functional operation of the device at these or any other
conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure
to absolute maximum rating conditions for extended periods may affect device reliability.
Electrical Characteristics
Parameter
Symbol
Condition
(VIN=1.0V, VOUT =2.8V, IOUT=0mA ,Ta=+250C)
Values
Min. Typ.
Unit
Max.
Start-Up Voltage
Power On Reset
Threshold
Operating V DD
Range
No-Load Input
Current
Switch- Off Input
Current
Shutdown Current
Feedback Reference
FB Input Current
LX Switch On-time
VST
IOUT=1mA
VDD
AT1305,AT1305A
VDD
AT1305B
IIN1
IOUT=0mA
IIN2 VIN=5V
IIN3 EN=0V, /ENPB=High
VFB Close Loop VDD =2.85V
IFB
VFB =1.2V
FS
VOUT =2.85V
0.7
-
2.0
1.65
-
-
-
1.176
-
-
0.8
-
V
2
-
V
-
5.5 V
5.5 V
87
-
μA
32
50 μA
1
10 μA
1.2 1.224 V
-
50 nA
1.75
-
μS
7F, No.9,PARK AVENUE. II, Science-Based Industrial Park, Hsinchu 300,Taiwan, R.O.C.
Tel: 886-3-563-0878 Fax: 886-3-563-0879
WWW: http://www.aimtron.com.tw
2/8/2006 REV:1.1
Email: service@aimtron.com.tw
3