English
Language : 

AMEOF5-JZ Datasheet, PDF (3/3 Pages) AIMTEC – 5 Watt | AC-DC Converter
O
Derating*
Free Air Convection
Series AMEOF5-JZ
5 Watt | AC-DC Converter
Free Air Convection at 25°C
100
100
80
Safe Operating Area
Input 110-240VAC or
60
135-320VDC
80
Safe Operating Area
60
40
40
20
0
- 2-520
0
55
20 40 60
8085 100
Ambient Temperature º C
*Power derating: for 85-110VAC and 240-264VAC input supply
20
0
85
(70)
110
(100)
240
(340)
Input Voltage VAC (VDC)
264
(400)
Recommended EMC class A external circuit:
FUSE
R
1A/250V
NTC
12Ω
Single Output
AC L
3
AC N
MOV
S14K350
CX1
0.1µF/
300V
C1 +
10µF/
400V
5
AC
7
1
14
DC
12
+ C2
+Vout
TVS
C3
0.1µF/50V
‐ Vout
CY1
1nF/400VAC
Recommended EMC class B external circuit:
FUSE
1A/250V
AC L
LCM
LDM
3.5mH 0.33mH
Single Output
NTC
3
12
AC N
MOV
S14K350
CX
0.1µF/
300VAC
CY3
1nF/
400VAC
CY2
1nF/
400VAC
+ C1
10µF/
400V
5
AC
7
1
TVS
DC
+ C2
10
+Vout
C3
0.1µF/50V
‐ Vout
GND
CY1
1nF/400VAC
Model
3.3 & 5 Vout
9 Vout
12 & 15 Vout
24 Vout
C2
220 µF / 35V
150 µF / 35V
TVS
7V
12V
20V
30V
Note: For Safety compliance we recommend minimum PCB trace distance of
3mm, primary to secondary circuit minimum distance between PCB traces of
6.4mm.
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 052e R0
Tel: +1 514 620 2722
3 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only