English
Language : 

AMEOF5-JZ Datasheet, PDF (1/3 Pages) AIMTEC – 5 Watt | AC-DC Converter
O
Series AMEOF5-JZ
5 Watt | AC-DC Converter
Picture Coming Soon
FEATURES:
Models
Single output
Model
AMEOF5-3.3SJZ
AMEOF5-5SJZ
AMEOF5-9SJZ
AMEOF5-12SJZ
AMEOF5-15SJZ
AMEOF5-24SJZ
AMEOF5-12SLJZ
AMEOF5-24SLJZ
 Input: 85-264VAC, 47-440Hz or 100-400VDC  I/O Isolation 3000VAC
 Operating temperature -25°C to +85°C
 Ultra slim open frame SIP
 Low power consumption ≤ 0.5W
 Over current protection
 Continuous short circuit protection
 Over voltage protection
 Class II power supply
Input Voltage
(VAC/Hz)
85-264/47-63
85-264/47-63
85-264/47-63
85-264/47-63
85-264/47-63
85-264/47-63
85-264/47-63
85-264/47-63
Input
Voltage
(VDC)
100-400
100-400
100-400
100-400
100-400
100-400
100-400
100-400
Full power
temperature
range
(ºC)
0 to +55
0 to +55
0 to +55
0 to +55
0 to +55
0 to +55
0 to +55
0 to +55
Output
Voltage
(V)
3.3
5
9
12
15
24
12
24
Output
Current max
(mA)
1000
1000
560
420
340
210
420
210
Maximum
capacitive
load
(µF)
2200
1500
680
470
330
100
470
100
Efficiency
(%)
67
74
75
76
77
79
76
79
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
Input Specifications
Parameters
Current
Inrush current <2ms
External fuse
Input dissipation
Leakage current
Conditions
115VAC
230VAC
115VAC
230VAC
Recommended slow blow type
No Load
CY(Input to Output) 1nF/400VAC
Typical


5
10
1
Maximum
200
100
0.5
250
Units
mA
mA
A
A
A
W
µA
Output Specifications
Parameters
Voltage accuracy
Line regulation
Load regulation
Ripple & Noise
Over current protection
Short circuit protection
Short circuit restart
Over Voltage protection
Hold up time
Conditions
Full load, 3.3V output
Full load, others
Full load
10% - 100% load
20MHz Bandwidth
Auto-recovery
115VAC
230VAC
Typical
≥110
Continuous
Auto-recovery
Zener diode clamp
20
80
Maximum
±3
±2
±0.5
±1.5
150
Units
%
%
%
mV p-p
% of I out
ms
ms
Isolation Specifications
Parameters
Tested I/O voltage
Isolation Resistance
Conditions
60 sec, 5mA leakage current
Typical
>1000
Rated
3000
Units
VAC
MΩ
www.aimtec.com
F 052e R0
Tel: +1 514 620 2722
1 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only