English
Language : 

AMEL1-5SAZ Datasheet, PDF (3/4 Pages) AIMTEC – AC-DC Converter
Environment Approval
Parameters
Wave form: Half sine wave
Conditions
Shock
Acceleration amplitude: 5gn
Bump duration: 30 ms
Number of bumps: 18 (3 in each direction for every axis)
Converter operation before and after test, body mounted (on chassis)
Test mode: Sweep sine
10-100Hz, speed 0.05Hz/s
Vibrations
Displacement: 1mm
Acceleration: 3g
3 loops 30min one cycle, 3h total, every axis tested
Converter operation before and after test, body mounted (on chassis)
Series AMEL1-AZ
1Watt | AC-DC Converter
Safety Specifications
Parameters
Agency approvals
cULus, CE, CB (under certification), CSA
Information technology Equipment
EMI - Conducted and radiated emission
Harmonic Current Emissions
Voltage fluctuations and flicker
Electrostatic Discharge Immunity
RF, Electromagnetic Field Immunity
Electrical Fast Transient/Burst Immunity
Surge Immunity (1KV)
RF, Conducted Disturbance Immunity
Power frequency Magnetic Field Immunity
Voltage dips, Short Interruptions Immunity
Canadian Safety Agency
IEC/EN/UL 60950-1:2006+A11:2009
EN55022, class B
IEC/EN 61000-3-2, (EN60555-2)
IEC/EN 61000-3-3, (EN60555-3)
IEC 61000-4-2
IEC 61000-4-3
IEC 61000-4-4
IEC 61000-4-5(SAZ &DAZ:Level2,SBAZ&DBAZ:Level 1)
IEC 61000-4-6
IEC 61000-4-8
IEC 61000-4-11
CAN/CSA-C22.2 NO. 60950-1-07
Pin Out Specifications
Pin
Single
1
NC
2
NC
3
+V Output
4
GND
5
No Pin
6
AC Input (L)
7
AC Input (N)
Dual
NC
NC
+V Output
GND
-V Output
AC Input (L)
AC Input (N)
www.aimtec.com
F 052e R8.C
Tel: +1 514 620 2722
3 of 4
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only