English
Language : 

AME3-CJZ Datasheet, PDF (3/3 Pages) AIMTEC – Input: 85-264VAC, 47-63Hz, or 100-370 VDC
Derating
Free Air Convection
Series AME3-CJZ
3 Watt | AC-DC / DC-DC Converter
Free Air Convection at 25°C
100
80
70 Safe Operating Area
60
Input 100-240VAC or
120-340VDC
40
20
0
- 2-520
0
55
70
20 40 60 80 100
Ambient Temperature º C
Application circuit
FUSE
1A/250V
AC L
Single Output
AC L
100
80
75
Safe Operating Area
60
50
40
20
0
85 100
(100) (120)
240
(340)
Input Voltage VAC (VDC)
264
(370)
4
+ Vout
AC N
MOV
S14K350
AC
AC N
DC
3
C1 C2
1µF/50V
+ TVS
- Vout
*GND connection not allowed
Class B compliance recommended circuit
FUSE
1A/250V
AC L
AC N
MOV
S14K350
LDM
LCM
4.7µH/2A 10-30mH
CX
0.1µF/
275VAC
CY1
1nF/
400VAC
CY2
1nF/
400VAC
Single Output
AC N
+Vout
AC
AC L
DC
- Vout
C1 C2 +
1µF/50V
+Vout
TVS
- Vout
GND
Model
3.3 & 5 Vout
9Vout
12 & 15 Vout
24 Vout
C2
TVS
150 µF / 35V
7V
120 µF / 35V
12V
120 µF / 35V
20V
68 µF / 35V
30V
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 052e R8
Tel: +1 514 620 2722
3 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only