English
Language : 

AME3-CJZ Datasheet, PDF (1/3 Pages) AIMTEC – Input: 85-264VAC, 47-63Hz, or 100-370 VDC
Click on Series name for product info on aimtec.com
Picture coming soon
FEATURES:
Series AME3-CJZ
3 Watt | AC-DC / DC-DC Converter
• I/O Isolation 3000VAC
• Operating Temp: -25°C to +70°C
• Input: 85-264VAC, 47-63Hz, or 100-370 VDC
• Over current and Over voltage Protection
• Class II Power supply
• Low no load consumption ≤ 0.3W
• Continuous Short Circuit Protection
Models
Single output
Model
AME3-3.3SCJZ
AME3-5SCJZ
AME3-9SCJZ
AME3-12SCJZ
AME3-15SCJZ
AME3-24SCJZ
Input Voltage
(VAC/Hz)
85-264/47-63
85-264/47-63
85-264/47-63
85-264/47-63
85-264/47-63
85-264/47-63
Input
Voltage
(VDC)
100-370
100-370
100-370
100-370
100-370
100-370
Temperature
range
(ºC)
-25 to +70
-25 to +70
-25 to +70
-25 to +70
-25 to +70
-25 to +70
Output
Voltage
(V)
3.3
5
9
12
15
24
Output
Current max
(mA)
700
600
330
250
200
125
Maximum
capacitive
Load
(µF)
6000
6000
1500
1500
1000
330
Efficiency
(%)
230
VAC
66
74
75
77
77
78
Input Specifications
Parameters
Current (full load)
Inrush current <2ms (cold start)
Leakage current
External fuse
Conditions
115 VAC
230 VAC
115 VAC
230 VAC
230VAC/50Hz, rms
Recommended slow blow type
Typical
65
30
10
20
0.1
1
Maximum
Units
mA
mA
A
A
mA
A
Output Specifications
Parameters
Voltage accuracy
Line regulation
Load regulation
Minimum load
Ripple & Noise
Hold up time
Conditions
3.3V output
Others
LL-HL, Full Load
10% - 100% load, nominal input
20MHz bandwidth, 115/230VAC, Full Load
230VAC
Typical
±3
±2
±0.5
±1
10
50
50
Maximum
100
Units
%
%
%
%
mV p-p
ms
Isolation Specifications
Parameters
Tested I/O voltage
Isolation Resistance
Conditions
60 sec
Typical
>1000
Rated
3000
Units
VAC
MΩ
General Specifications
Parameters
Switching frequency
Over Current protection
Over Voltage protection
Short circuit protection
Operating temperature
Storage temperature
Temperature coefficient
Maximum Case temperature
Humidity
Case material
www.aimtec.com
F 052e R8
Conditions
Auto recovery
3.3/5V output
9V output
12/15V output
24V output
With derating above 55°C
Typical
115
≥110
Auto recovery, Continuous
-25 to +70
-25 to +105
±0.02
Non condensing
Plastic resin (flammability to UL 94V-0)
Tel: +1 514 620 2722
1 of 3
Maximum
7.5
12
20
30
95
95
Units
KHz
% of Iout
VDC
°C
°C
%/°C
°C
% RH
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only