English
Language : 

AMER150-AZ_16 Datasheet, PDF (2/11 Pages) AIMTEC – AC-DC Constant Current or Constant Voltage LED Driver
Series AMER150-AZ
up to 6.3A | AC-DC / DC-DC | LED Driver / Converter
Output Specifications
Parameters
Conditions
Typical
Maximum
Units
Current accuracy
±3
%
Line regulation
LL-HL
±2
%
Load regulation
0-100% load
±3
%
Ripple & Noise ④
200
mV p-p
Hold-up time (min)
40
ms
Current adjustment range⑤
100-10
%
④ Ripple and Noise are measured at 20MHz bandwidth by using a 0.1μF (M/C) or (C/C) and 47µF (E/C) parallel capacitor.
⑤Note: from 0% to 10% dimming adjustment signal instability may be present.
Isolation Specifications
Parameters
Tested voltage
I/O
I/FG
O/FG
Isolation resistance
Conditions
3sec
500 VDC
Typical
>1000
Maximum
3750
2000
500
Units
VAC
VAC
VAC
MΩ
General Specifications
Parameters
Switching frequency
Over current protection
Over voltage protection
Short circuit protection
Conditions
Typical
Maximum
100
AMER150-50300AZ
3.07
AMER150-36420AZ
4.27
AMER150-24630AZ
6.37
Refer to Constant Current vs. Constant Voltage Mode curve
Auto recovery
Units
KHz
A
Operating temperature
Maximum case temperature
Storage temperature
Temperature coefficient
Cooling
Humidity
Case material
Potting
Wires
Weight
Dimensions (L X H X W)
MTBF
See derating table
-40 to +80
100
-40 to +95
±0.02
Free air convection
Non condensing
95
Aluminum
Epoxy (IP68 rated)
UL1015 18AWG input & 14AWG output *20CM
900
7.13 x 2.32 x 1.85 inches 181.00 x 59.00 x 47.00 mm
>400,000 hrs (MIL-HDBK-217F at +25°C)
oC
oC
oC
% / oC
% RH
g
Safety Specifications
Parameters
Agency approvals cULus, CE
UL8750, UL60950-1, EN55022, class B, EN60529(IP68), EN61347-1, EN61347-2-13
Information Technology Equipment
EN55022 Class B
Harmonic Current Emissions
IEC/EN 61000-3-2, Class C
Voltage fluctuations and flicker
IEC/EN 61000-3-3, (EN60555-3)
Electrostatic Discharge Immunity
IEC 61000-4-2 Level 3
Standards
RF, Electromagnetic Field Immunity
IEC 61000-4-3 Level 2
Electrical Fast Transient / Burst Immunity
IEC 61000-4-4 Level 2
Surge Immunity
IEC 61000-4-5 Level 3
RF, Conducted Disturbance Immunity
IEC 61000-4-6 Level 2
Power frequency Magnetic Field Immunity
IEC 61000-4-8 Level 1
Voltage dips, Short Interruptions Immunity
IEC 61000-4-11
www.aimtec.com
F 052.1e R3.AF
Tel: +1 514 620 2722
2 of 11
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only