English
Language : 

AMER150-AZ_16 Datasheet, PDF (1/11 Pages) AIMTEC – AC-DC Constant Current or Constant Voltage LED Driver
Click on Series name for product info on aimtec.com
Series AMER150-AZ
up to 6.3A | AC-DC / DC-DC | LED Driver / Converter
FEATURES:
 AC-DC Constant Current or Constant
Voltage LED Driver
 Over Voltage Protection
 Over Current Protection
 Input range 90-305VAC/47-440Hz
 Waterproof Case rated IP68
 High Efficiency up to 89%
 Power Factor Correction
 Operating temperature -40 to 80°C
 Short Circuit Protection
Models
Single output
 Dimmable via resistive
 5 Years Limited Warranty
Model
Max
Output
Power
(W)①
Output
Voltage
Range
(V)③
Output
Current
(A)③
Input
Voltage
(VAC/Hz)
Input
Voltage Mode of Operation
(VDC)
Efficiency
(%)
115
230
277
VAC
VAC
VAC
AMER150-50300AZ
150
36-50
Constant Current
87 89 89
0-3
90-305/47-440 130-430 Constant Voltage②
87
88
89
AMER150-36420AZ
150
24-36
0-4.16
90-305/47-440 130-430
Constant Current
Constant Voltage②
86
86
88
88
88
88
AMER150-24630AZ
151.2
12-24
0-6.3
Constant Current
85 87 87
90-305/47-440 130-430 Constant Voltage②
85
87
87
Add Suffix “-F” No dimming option
① Exceeding the maximum output power will permanently damage the converter
② The dimming feature is not supported when units are used in Constant Voltage mode only, Aimtec suggests to order “-F” No dimming
option in this case.
③ In constant current mode output current is maximum shown, in constant voltage mode output voltage is the maximum shown.
All All models can be ordered with optional North American colour input wires (black (L), white (N), green (GND)). Add “–NA” to part number
when ordering.
NOTE: Aimtec limited warranty of 5 years is valid based on product operation at datasheet specifications at ambient temperature of 25°C,
humidity<75%, nominal input voltage (115/230/277VAC) and at rated output load unless otherwise specified. See
http://www.aimtec.com/terms-sale
AMER150-AZ’s AC/DC LED drivers have electrical safeguards designed within to protect it from conventional electrical abnormalities with
the levels listed in the safety table. Applications for use within rural agricultural, heavy industrial, and other areas or regions which are
prone to ‘dirty’ electrical conditions which would subject any of the above models to excessive voltages surges or spikes, may damage or
cause early life failure of product. In this case consideration should be made by the end user to ensure that adequate line or mains surge
suppression is installed in front of Aimtec device to ensure the longevity of the products. Failure to identify excessive line surges violations
prior to installation may damage sensitive equipment permanently.
Input Specifications
Parameters
Current (full load)
Inrush current <2ms (cold start)
Leakage current
Power factor
External fuse
Start-up time
Conditions
115 VAC
230 VAC
277 VAC
115 VAC
230 VAC
277 VAC
I/O
I/FG, O/FG
115 VAC
230 VAC
277 VAC
Recommended slow blow type
Typical
0.98
0.94
0.92
3.5
900
Maximum
2000
1000
900
50
75
90
0.25
3.5
Units
mA
mA
mA
A
A
A
mA
mA
A
ms
www.aimtec.com
F 052.1e R3.AF
Tel: +1 514 620 2722
1 of 11
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only