English
Language : 

AM10CW-NZ Datasheet, PDF (2/3 Pages) AIMTEC – 10 Watt | DC-DC Converter
Isolation Specifications
Parameters
Tested I/O voltage
Resistance
Capacitance
Conditions
60 sec, <1mA
500VDC
I/O, 100KHz/0.1V
Typical
1500
1000
Series AM10CW-NZ
10 Watt | DC-DC Converter
Maximum
>1000
Units
VDC
MOhm
pF
Output Specifications
Parameters
Voltage accuracy
Voltage balance (Dual Output Models)
Over voltage protection
Over current protection
Short Circuit protection
Short circuit restart
Line voltage regulation (Single)
Line voltage regulation (Dual)
Load voltage regulation (Single)
Load voltage regulation (Dual)
Cross Regulation (Dual Output Models)
Temperature coefficient
Ripple & Noise
Transient recovery time
Transient recovery deviation
Conditions
5% to 100% load
Balanced Load
Full load, LL to HL
Full load, LL to HL
5% to 100% load
5% to 100% load
50% load on one output & 10-100%
load on second load
100% load
20MHz Bandwidth, 5-100% load
25% load step change
25% load step change
Typical
±2
110-160
110-190
Continuous
Auto-Recovery
±5
Maximum
±3
±1.5
Units
%
%
% of Vout
% of Iout
±0.5
±1
±1
±1.5
±0.03
80
500
±5
% of Vin
% of Vin
%
%
%
%/oC
mV p-p
µs
%
General Specifications
Parameters
Switching frequency
Operating temperature
Storage temperature
Maximum case temperature
Cooling
Humidity
Case material
Weight
Dimensions (L x W x H)
MTBF
Maximum soldering temperature
Conditions
Typical
Maximum
100% load
350
See derating curve
-40 to +85
-55 to +125
100
Free air convection
95
Aluminum Alloy
15
1 x 1 x 0.46 inches 25.40 x 25.40 x 11.70 mm
>1,000,000 hours (MIL-HDBK -217F, Ground Benign, t=+25oC)
1.5mm from case for 10 sec
300
Units
KHz
oC
oC
oC
% RH
g
oC
Environmental Specifications
Parameters
Vibration
Test mode
Acceleration
10-55Hz
10G, 30min one cycle, every axis tested
Safety Specifications
Parameters
Approval
CE, UL, pending
EN 55022, class B (with the recommended EMC circuit)
Electrostatic Discharge Immunity
IEC 61000-4-2, Contact ±4KV, Criteria B
RF, Electromagnetic Field Immunity
IEC 61000-4-3, 10V/m, Criteria A
Standards
Electrical Fast Transient / Burst Immunity
Surge Immunity
IEC 61000-4-4, ±2KV, Criteria B (with the recommended EMC circuit)
IEC 61000-4-5, ±2KV, Criteria B (with the recommended EMC circuit)
RF, Conducted Disturbance Immunity
IEC 61000-4-6, 3 Vrms, Criteria A
Voltage dips, Short Interruptions & Voltage IEC 61000-4-29: 0-70%, Criteria B
variations Immunity
www.aimtec.com
F 051e R13
Tel: +1 514 620 2722
2 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only