English
Language : 

AMEPR30-AZ_16 Datasheet, PDF (1/15 Pages) AIMTEC – AC-DC Constant Current or Constant Voltage LED Driver
FEATURES:
Click on Series name for product info on aimtec.com
Series AMEPR30-AZ
up to 2.5A | AC-DC / DC-DC | LED Driver / Converter
Models
Single output
 AC-DC Constant Current or Constant
Voltage LED Driver
 Input range 90-305VAC/47-440Hz
 High efficiency up to 84%
 Operating temperature -40 to 85°C
 Dimmable via resistive / 0-10Vdc / PWM
 5 Years Limited Warranty
 Over temperature protection
 Over current protection
 Waterproof case rated IP68
 Power Factor Correction
 Short circuit protection
Model
Max
Output
Power
(W)①
Output
Voltage
Range
(V)③
Output
Current
(A)③
Input
Voltage
(VAC/Hz)
Input
Voltage
(VDC)
Mode of Operation
Efficiency
(%)
115 230 277
VAC
VAC
VAC
AMEPR30-5070AZ
35
36-50
Constant Current
84 83 83
0.7
90-305/47-440 130-430
Constant Voltage②
84
83
83
AMEPR30-4864AZ
30.7
36-48
Constant Current
84 83 83
0.64
90-305/47-440 130-430
Constant Voltage②
84
83
83
AMEPR30-36100AZ
36
24-36
Constant Current
84 83 83
1
90-305/47-440 130-430
Constant Voltage②
84
83
83
AMEPR30-24140AZ 33.6
12-24
Constant Current
83 82 82
1.4
90-305/47-440 130-430
Constant Voltage②
83
82
82
AMEPR30-12250AZ
30
5-12
2.5
90-305/47-440 130-430
Constant Current
Constant Voltage②
81
81
80
80
80
80
① Exceeding the maximum output power will permanently damage the converter.
② The dimming feature is not supported when units are used in Constant Voltage mode only.
③ In constant current mode output current is maximum shown, in constant voltage mode output voltage is the maximum shown. All models
can be ordered with optional North American colour input wires (black (L), white (N), green (GND)). Add “–NA” to part number when
ordering.
NOTE: Aimtec limited warranty of 5 years is valid based on product operation at datasheet specifications at ambient temperature of 25°C,
humidity<75%, nominal input voltage (115/230/277VAC) and at rated output load unless otherwise specified. See
http://www.aimtec.com/terms-saleAMEPR30-AZ’s AC/DC LED drivers have electrical safeguards designed within to protect it from
conventional electrical abnormalities with the levels listed in the safety table. Applications for use within rural agricultural, heavy industrial,
and other areas or regions which are prone to ‘dirty’ electrical conditions which would subject any of the above models to excessive
voltages surges or spikes, may damage or cause early life failure of product. In this case consideration should be made by the end user to
ensure that adequate line or mains surge suppression is installed in front of Aimtec device to ensure the longevity of the products. Failure
to identify excessive line surges violations prior to installation may damage sensitive equipment permanently.
Input Specifications
Parameters
Current (full load)
Inrush current <2ms (cold start)
Leakage current
Power factor
External fuse
Start-up time
Conditions
115 VAC
230 VAC
277 VAC
115 VAC
230 VAC
277 VAC
I/O
I/FG, O/FG
115 VAC
230 VAC
277 VAC
Recommended slow blow type
Typical
0.96
0.90
0.85
1
450
Maximum
430
250
210
25
40
55
0.25
3.5
Units
mA
mA
mA
A
A
A
mA
mA
A
ms
www.aimtec.com
F 052.1e R3.AG
Tel: +1 514 620 2722
1 of 15
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only