English
Language : 

AMEL20-AZ_16 Datasheet, PDF (1/5 Pages) AIMTEC – 20 Watt | AC-DC / DC-DC Converter
FEATURES:
Click on Series name for product info on aimtec.com
Series AMEL20-AZ
20 Watt | AC-DC / DC-DC Converter
 I/O Isolation 3000VAC
 Operating Temp: -40 oC to +80 oC
 Over load and, Over Voltage Protection
 Input: 90-305VAC, 47-440Hz, or 130-430VDC
 Energy Star compliant
 Ultra small package
 Up to 81% efficiency
 Short Circuit Protection
Models
CB
Single output
Model
Input Voltage
(VAC/Hz)
Input
Voltage
(VDC)
Max
Output
wattage
(W)
Output
Voltage(V)
Output
Current
max (A)
Maximum
capacitive
load (µF)
Efficiency
(%)
115 230 277
VAC
VAC
VAC
AMEL20-3.3SAZ 90-305/47-440 130-430
13.2
3.3
4
5600
73 73 72
AMEL20-5SAZ
90-305/47-440 130-430
20
5
4
4700
77 77 76
AMEL20-12SAZ
90-305/47-440
130-430
20
12
1.66
3300
80 80 80
AMEL20-15SAZ
90-305/47-440
130-430
20
15
1.33
2200
81 80 80
AMEL20-24SAZ
90-305/47-440
130-430
20
24
0.84
1000
79 80 79
Note: Optional mounting plate version can be order by adding “-ST” suffix to part number (ex. AMEL20-5SMAZ-ST)
Input Specifications
Parameters
Current (full load)
Inrush current <2ms (cold start)
Leakage current
External fuse
Input dissipation
Start-up time
Conditions
115 VAC
230 VAC
277 VAC
115 VAC
230 VAC
277 VAC
Recommended slow blow type
(115/230/277 VAC)
Typical




1.5
≦0.5
150
Maximum
460
290
260
30
50
55
0.25
Units
mA
mA
mA
A
A
A
mA
A
W
ms
Output Specifications
Parameters
Voltage accuracy
Line regulation
Load regulation
Transient recovery time
Transient response deviation
Ripple & Noise*
Hold-up time
Conditions
(LL-HL)
0-100% load
25% load step
Typical
±2
±1
±2
500
±2
200
10
*Ripple and Noise are measured at 20MHz bandwidth by using a 0.1μF (M/C) and 47µF (E/C) parallel capacitor.
Maximum
Units
%
%
%
µs
% of Vout
mV p-p
ms
Isolation Specifications
Parameters
Tested I/O voltage
Isolation resistance
Conditions
60 sec
Typical
>1000
Rated
3000
Units
VAC
MΩ
General Specifications
Parameters
Switching frequency
Over load protection
Over voltage protection
Conditions
Foldback
Typical
65
130
Zener Diode Clamp
Maximum
Units
KHz
%
www.aimtec.com
F 052e R8.H
Tel: +1 514 620 2722
1 of 5
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only