FEATURES:
 SMD Package
 Wide (2:1) Input Range
 1500 VDC Isolation
 Continuous Short Circuit Protection
Series AM2LV-NZ
2 Watt | DC-DC Converter
 Operating Temperature: -40°C To +85°C
 Regulated Single / Dual Output
 MTBF >1,000,000 Hours
 RoHS Compliant
Models
Single output
Model
AM2LV-1203S-NZ
AM2LV-1205S-NZ
AM2LV-1212S-NZ
AM2LV-2403S-NZ
AM2LV-2405S-NZ
AM2LV-2412S-NZ
Input Voltage
(V)
9-18
9-18
9-18
18-36
18-36
18-36
Output Voltage
(V)
3.3
5
12
3.3
5
12
Output Current
max (mA)
500
400
167
500
400
167
Isolation
(VDC)
1500
1500
1500
1500
1500
1500
Efficiency
(%)
70
74
78
72
76
80
Models
Dual output
Model
Input Voltage Output Voltage Output Current
(V)
(V)
max (mA)
Isolation
(VDC)
Efficiency
(%)
AM2LV-1209D-NZ
9-18
±9
±111
1500
76
AM2LV-1212D-NZ
9-18
±12
±83
1500
78
AM2LV-1215D-NZ
9-18
±15
±67
1500
80
AM2LV-2405D-NZ
18-36
±5
±200
1500
74
AM2LV-2409D-NZ
18-36
±9
±111
1500
76
AM2LV-2412D-NZ
18-36
±12
±83
1500
78
AM2LV-2415D-NZ
18-36
±15
±67
1500
80
NOTE: Unless otherwise specified, all specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input
voltage and at rated output load.
Input Specifications
Parameters
Voltage range
Absolute Maximum Rating
Peak Input Voltage time
Nominal
12
24
12
24
Typical
9-18
18-36
Maximum
22
40
100
Units
VDC
VDC
ms
Isolation Specifications
Parameters
Tested I/O voltage
Resistance
Capacitance
Conditions
60 sec
At 500 VDC
Input to Output
Typical
1000
85
Rated
1500
Units
VDC
MOhm
pF
Output Specifications
Parameters
Voltage accuracy
Short Circuit protection
Short circuit restart
Line voltage regulation (Single)
Load voltage regulation (Single)
Load voltage regulation (Dual)
Temperature coefficient
www.aimtec.com
F 051e R8.G
Conditions
Typical
±5
Continuous
Auto-Recovery
From Low in to High In
±0.5
From 10% to 100% load
±1
From 10% to 100% load
Each output loaded within 5% of each other
±5
±0.03
Tel: +1 514 620 2722
1 of 4
Maximum
Units
%
%
%
%
%/oC
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only