English
Language : 

APT40GF120JRD Datasheet, PDF (3/4 Pages) Advanced Power Technology – The Fast IGBT™ is a new generation of high voltage power IGBTs
APT40GF120JRD
ULTRAFAST SOFT RECOVERY PARALLEL DIODE
MAXIMUM RATINGS (FRED)
All Ratings: TC = 25°C unless otherwise specified.
Symbol Characteristic / Test Conditions
APT40GF120JRD
UNIT
VR
Maximum D.C. Reverse Voltage
VRRM Maximum Peak Repetitive Reverse Voltage
VRWM Maximum Working Peak Reverse Voltage
IF(AV) Maximum Average Forward Current (TC = 60°C, Duty Cycle = 0.5)
IF(RMS)
Y IFSM
RMS Forward Current
Non-Repetitive Forward Surge Current (TJ = 45°C, 8.3mS)
AR STATIC ELECTRICAL CHARACTERISTICS (FRED)
IN Symbol Characteristic / Test Conditions
MIN
IM VF
Maximum Forward Voltage
IF = 60A
IF = 120A
IF = 60A, TJ = 150°C
PREL DYNAMIC CHARACTERISTICS (FRED)
Symbol Characteristic
MIN
1200
60
100
540
Volts
Amps
TYP MAX UNIT
2.5
2.0
Volts
2.0
TYP MAX UNIT
trr1
trr2
trr3
tfr1
tfr2
IRRM1
IRRM2
Qrr1
Qrr2
Vfr1
Vfr2
diM / dt
Reverse Recovery Time, IF = 1.0A, diF/dt = -15A/µs, VR = 30V, TJ = 25°C
Reverse Recovery Time
TJ = 25°C
IF = 60A, diF/dt = -480A/µs, VR = 650V
TJ = 100°C
Forward Recovery Time
TJ = 25°C
IF = 60A, diF/dt = 480A/µs, VR = 650V
TJ = 100°C
Reverse Recovery Current
TJ = 25°C
IF = 60A, diF/dt = -480A/µs, VR = 650V
TJ = 100°C
Recovery Charge
TJ = 25°C
IF = 60A, diF/dt = -480A/µs, VR = 650V
TJ = 100°C
Forward Recovery Voltage
TJ = 25°C
IF = 60A, diF/dt = 480A/µs, VR = 650V
TJ = 100°C
Rate of Fall of Recovery Current
TJ = 25°C
IF = 60A, diF/dt = -480A/µs, VR =650V
TJ = 100°C
70
85
70
130
ns
170
170
18
30
Amps
29
40
630
nC
1820
12
Volts
12
900
A/µs
600