DYNAMIC CHARACTERISTICS
Symbol Characteristic
Test Conditions
APT50GP60B
MIN TYP MAX UNIT
Cies
Coes
Cres
VGEP
Qg
Qge
Qgc
Input Capacitance
Output Capacitance
Reverse Transfer Capacitance
Gate-to-Emitter Plateau Voltage
Total Gate Charge 3
Gate-Emitter Charge
Gate-Collector ("Miller ") Charge
Capacitance
VGE = 0V, VCE = 25V
f = 1 MHz
Gate Charge
VGE = 15V
VCE = 300V
IC = 50A
SSOA Safe Operating Area
TJ = 150°C, RG = 5Ω, VGE = 190
15V, L = 100µH,VCE = 600V
td(on)
tr
td(off)
tf
Eon1
Eon2
Eoff
Turn-on Delay Time
Current Rise Time
Turn-off Delay Time
Current Fall Time
Turn-on Switching Energy 4
Turn-on Switching Energy (Diode) 5
Turn-off Switching Energy 6
Inductive Switching (25°C)
VCC = 400V
VGE = 15V
IC = 50A
RG = 5Ω
TJ = +25°C
td(on)
tr
td(off)
tf
Eon1
Eon2
Eoff
Turn-on Delay Time
Current Rise Time
Turn-off Delay Time
Current Fall Time
Turn-on Switching Energy 4
Turn-on Switching Energy (Diode) 5
Turn-off Switching Energy 6
Inductive Switching (125°C)
VCC = 400V
VGE = 15V
IC = 50A
RG = 5Ω
TJ = +125°C
THERMAL AND MECHANICAL CHARACTERISTICS
Symbol Characteristic
MIN
5700
465
30
7.5
165
40
50
19
36
83
60
465
837
637
19
36
116
86
465
1261
1058
TYP
MAX
pF
V
nC
A
ns
µJ
ns
µJ
UNIT
RΘJC
RΘJC
WT
Junction to Case (IGBT)
Junction to Case (DIODE)
Package Weight
.20
N/A
5.90
°C/W
gm
1 Repetitive Rating: Pulse width limited by maximum junction temperature.
2 For Combi devices, Ices includes both IGBT and FRED leakages
3 See MIL-STD-750 Method 3471.
4 Eon1 is the clamped inductive turn-on-energy of the IGBT only, without the effect of a commutating diode reverse recovery current
adding to the IGBT turn-on loss. (See Figure 24.)
5 Eon2 is the clamped inductive turn-on energy that includes a commutating diode reverse recovery current in the IGBT turn-on switching
loss. A Combi device is used for the clamping diode as shown in the Eon2 test circuit. (See Figures 21, 22.)
6 Eoff is the clamped inductive turn-off energy measured in accordance with JEDEC standard JESD24-1. (See Figures 21, 23.)
7 Continuous current limited by package lead temperature.
APT Reserves the right to change, without notice, the specifications and information contained herein.