DYNAMIC CHARACTERISTICS
APT451GP120B
Symbol Characteristic
Test Conditions
MIN TYP MAX UNIT
Cies Input Capacitance
Capacitance
3935
Coes Output Capacitance
VGE = 0V, VCE = 25V
300
pF
Cres Reverse Transfer Capacitance
f = 1 MHz
55
VGEP Gate-to-Emitter Plateau Voltage
Gate Charge
7.5
V
Qg
Total Gate Charge 3
Qge Gate-Emitter Charge
Qgc Gate-Collector ("Miller ") Charge
VGE = 15V
VCE = 600V
IC = 45A
185
25
nC
80
RBSOA Safe Operating Area
TJ = 150°C, RG = 5Ω, VGE = 170
A
15V, L = 100µH,VCE = 960V
td(on) Turn-on Delay Time
Inductive Switching (25°C)
18
tr
td(off)
tf
Eon1
Eon2
Current Rise Time
Turn-off Delay Time
Current Fall Time
Turn-on Switching Energy 4
Turn-on Switching Energy (Diode) 5
VCC = 600V
VGE = 15V
IC = 45A
RG = 5Ω
TJ = +25°C
29
ns
102
38
900
1869
µJ
Eoff Turn-off Switching Energy 6
904
td(on) Turn-on Delay Time
Inductive Switching (125°C)
18
tr
td(off)
tf
Eon1
Eon2
Current Rise Time
Turn-off Delay Time
Current Fall Time
Turn-on Switching Energy 4 4
Turn-on Switching Energy (Diode) 55
VCC = 600V
VGE = 15V
IC = 45A
RG = 5Ω
TJ = +125°C
29
ns
151
79
900
3078
µJ
Eoff
Turn-off Switching Energy 66
2254
THERMAL AND MECHANICAL CHARACTERISTICS
Symbol Characteristic
MIN TYP MAX UNIT
RΘJC
RΘJC
WT
Junction to Case (IGBT)
Junction to Case (DIODE)
Package Weight
.20
°C/W
N/A
5.9
gm
1 Repetitive Rating: Pulse width limited by maximum junction temperature.
2 For Combi devices, Ices includes both IGBT and FRED leakages
3 See MIL-STD-750 Method 3471.
4 Eon1 is the clamped inductive turn-on-energy of the IGBT only, without the effect of a commutating diode reverse recovery current
adding to the IGBT turn-on loss. (See Figure 24.)
5 Eon2 is the clamped inductive turn-on energy that includes a commutating diode reverse recovery current in the IGBT turn-on switching
loss. (See Figures 21, 22.)
6 Eoff is the clamped inductive turn-off energy measured in accordance wtih JEDEC standard JESD24-1. (See Figures 21, 23.)
7 Continuous current limited by package lead temperature.
APT Reserves the right to change, without notice, the specifications and information contained herein.