English
Language : 

APT15GT120BRDQ1 Datasheet, PDF (2/9 Pages) Advanced Power Technology – Thunderbolt IGBT
DYNAMIC CHARACTERISTICS
Symbol
Cies
Coes
Cres
VGEP
Qg
Qge
Qgc
Characteristic
Input Capacitance
Output Capacitance
Reverse Transfer Capacitance
Gate-to-Emitter Plateau Voltage
Total Gate Charge 3
Gate-Emitter Charge
Gate-Collector ("Miller ") Charge
SSOA Switching Safe Operating Area
td(on)
tr
td(off)
tf
Eon1
Eon2
Eoff
td(on)
tr
td(off)
tf
Eon1
Eon2
Eoff
Turn-on Delay Time
Current Rise Time
Turn-off Delay Time
Current Fall Time
Turn-on Switching Energy 4
Turn-on Switching Energy (Diode) 5
Turn-off Switching Energy 6
Turn-on Delay Time
Current Rise Time
Turn-off Delay Time
Current Fall Time
Turn-on Switching Energy 4 4
Turn-on Switching Energy (Diode) 55
Turn-off Switching Energy 6
APT15GT120BRDQ1(G)
Test Conditions
MIN TYP MAX UNIT
Capacitance
1070
VGE = 0V, VCE = 25V
f = 1 MHz
100
pF
65
Gate Charge
10
V
VGE = 15V
VCE = 600V
IC = 15A
105
10
nC
60
TJ = 150°C, RG = 5Ω, VGE =
15V, L = 100µH,VCE = 960V
45
A
Inductive Switching (25°C)
10
VCC = 800V
VGE = 15V
IC = 15A
RG = 5Ω
TJ = +25°C
11
ns
85
35
585
800
µJ
260
Inductive Switching (125°C)
10
VCC = 800V
VGE = 15V
IC = 15A
RG = 5Ω
TJ = +125°C
11
ns
95
42
590
1440
µJ
340
THERMAL AND MECHANICAL CHARACTERISTICS
Symbol
RθJC
RθJC
WT
Characteristic
Junction to Case (IGBT)
Junction to Case (DIODE)
Package Weight
MIN TYP MAX UNIT
.50
1.18
°C/W
5.9
gm
1 Repetitive Rating: Pulse width limited by maximum junction temperature.
2 For Combi devices, Ices includes both IGBT and FRED leakages
3 See MIL-STD-750 Method 3471.
4 Eon1 is the clamped inductive turn-on energy of the IGBT only, without the effect of a commutating diode reverse recovery current
adding to the IGBT turn-on loss. Tested in inductive switching test circuit shown in figure 21, but with a Silicon Carbide diode.
5 Eon2 is the clamped inductive turn-on energy that includes a commutating diode reverse recovery current in the IGBT turn-on switching
loss. (See Figures 21, 22.)
6 Eoff is the clamped inductive turn-off energy measured in accordance with JEDEC standard JESD24-1. (See Figures 21, 23.)
APT Reserves the right to change, without notice, the specifications and information contained herein.