English
Language : 

UG-194 Datasheet, PDF (9/20 Pages) Analog Devices – Evaluation Board for the ADE7953 Single Phase Energy Metering IC
Evaluation Board User Guide
EVALUATION SOFTWARE FUNCTIONS
The ADE7953 evaluation software allows access to all registers
and features of the ADE7953 using SPI, I2C, or UART communi-
cation. The communication mode and speed should be set in the
main window (see Figure 7). The menu options available are
• Active Energy
• Reactive Energy
• Apparent Energy
• Waveform Sampling
• Interrupts
• Power Quality Information
• Read and Write Registers
• Access All Registers
• Reset ADE7953
• EXIT (stops LabVIEW)
These options provide access to all internal registers and allow
the evaluation of ADE7953 performance. To access these func-
tions, click the desired option in the MENU box (see Figure 7).
Clicking an option in the MENU box displays a window where
the specific function can be accessed. Each window includes an
EXIT button that should be used to return to the main window.
Note that only one option from the MENU box can be open at a
time; click EXIT to return to the main window before choosing
another option from the MENU box.
ACTIVE ENERGY
The Active Energy window is shown in Figure 10. This window
allows access to all registers associated with the active energy
measurement.
UG-194
The tabs at the top of the window allow registers associated
with Current Channel A or Current Channel B to be accessed.
A register can be read by clicking READ All Registers. Register
modifications can be made directly on the signal path diagram;
these modifications are written to the part by clicking WRITE
All Registers.
From the Active Energy window, the CF Outputs window can
be accessed by clicking CF Output. Clicking CF Output opens
the window shown in Figure 9.
Figure 9. CF Outputs Window
From this window, the functionality of the CF1 and CF2 output
pins can be selected.
Figure 10. Active Energy Window
Rev. A | Page 9 of 20