English
Language : 

OP77_02 Datasheet, PDF (7/16 Pages) Analog Devices – Next Generation OP07 Ultralow Offset Voltage Operational Amplifier
ABSOLUTE MAXIMUM RATINGS1
Supply Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± 22 V
Differential Input Voltage . . . . . . . . . . . . . . . . . . . . . . . ± 30 V
Input Voltage2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± 22 V
Output Short-Circuit Duration . . . . . . . . . . . . . . . . . Indefinite
Storage Temperature Range
J and Z Packages . . . . . . . . . . . . . . . . . . . . –65∞C to +150∞C
Operating Temperature Range
OP77A . . . . . . . . . . . . . . . . . . . . . . . . . . . –55∞C to +125∞C
OP77E, OPP77F (J, Z) . . . . . . . . . . . . . . . . –25∞C to +85∞C
Junction Temperature (Tj) . . . . . . . . . . . . . –65∞C to +150∞C
Lead Temperature (Soldering, 60 sec.) . . . . . . . . . . . . . 300∞C
NOTES
1Absolute Maximum Ratings apply to both DICE and packaged parts, unless
otherwise noted.
2For supply voltages less than ± 22 V, the absolute maximum input voltage is
equal to the supply voltage.
Package Type
␪jAء
␪jC
Unit
TO-99 (J)
8-Lead Hermetic DIP (Z)
150
18
148
16
∞C/W
∞C/W
NOTE
␪ءjA is specified for worst-case mounting conditions, i.e., ␪jA is specified for
device in socket for TO, CERDIP, P-DIP, and PLCC packages; ␪jA is specified
for device soldered to printed circuit board for SO package.
BONDING DIAGRAM
OP77
1. BALANCE
2. INVERTING INPUT
3. NONINVERTING INPUT
4. V-
6. OUTPUT
7. V+
8. BALANCE
DIE SIZE 0.093 ؋ 0.057 inch, 5301 sq. mm
(2.36 ؋ 1.45 mm, 3.42 sq. mm)
ORDERING GUIDE
Package Options
CERDIP*
TO-99
8-Lead
OP77EJ
OP77FJ
OP77AZ
OP77EZ
OP77FZ
Ø¡Not for new designs; obsolete April 2002.
Operating
Temperature
Range
MIL
IND
IND
For Military processed devices, please refer to the Standard
Microcircuit Drawing (SMD) available at
www.dscc.dla.mil/programs/milspec/default.asp
SMD Part Number ADI Equivalent
5962-87738012A
5962-8773802GA
5962-8773802PA
OP77BRCMDA
OP77AJMDA
OP77AZMDA
CAUTION
ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily
accumulate on the human body and test equipment and can discharge without detection. Although
the OP77 features proprietary ESD protection circuitry, permanent damage may occur on devices
subjected to high-energy electrostatic discharges. Therefore, proper ESD precautions are
recommended to avoid performance degradation or loss of functionality.
WARNING!
ESD SENSITIVE DEVICE
REV. C
–7–