OP77–SPECIFICATIONS
ELECTRICAL SPECIFICATIONS (@ Vs = ؎15 V, TA = 25؇C, unless otherwise noted.)
Parameter
Symbol Conditions
OP77A
Min Typ
Max Unit
INPUT OFFSET VOLTAGE
VOS
10
25
mV
LONG-TERM INPUT OFFSET
VOLTAGE STABILITY1
DVOS/Time
0.2
mV/Mo
INPUT OFFSET CURRENT
IOS
0.3
nA
INPUT BIAS CURRENT
IB
INPUT NOISE VOLTAGE2
enp-p
INPUT NOISE VOLTAGE DENSITY2 en
INPUT NOISE CURRENT2
inp-p
INPUT NOISE CURRENT DENSITY2 in
0.1 Hz to 10 Hz
fO = 10 Hz
fO = 100 Hz
fO = 1000 Hz
0.1 Hz to10 Hz
fO = 10 Hz
fO = 100 Hz
fO = 1000 Hz
–0.2 1.2
0.35
10.3
10.0
9.6
14
0.32
0.14
0.12
2.0 nA
0.6
mV p-p
18.0 nV/÷Hz
13.0
11.0
30
pA p-p
0.80 pA/÷Hz
0.23
0.17
INPUT RESISTANCE
Differential Mode3
Common Mode
RIN
RINCM
26
45
MV
200
GV
INPUT VOLTAGE RANGE
IVR
± 13 ± 14
V
COMMON-MODE
REJECTION RATIO
CMRR
VCM = ± 13 V
0.1
1.0
mV/V
POWER SUPPLY
REJECTION RATIO
PSRR
VS = ± 3 V to ± 18 V
0.7
3
mV/V
LARGE-SIGNAL
VOLTAGE GAIN
AVO
RL ≥ 2 kW ≥ VO = ± 10V
5000 12000
V/mV
OUTPUT VOLTAGE SWING
VO
RL ≥ 10 kW
RL ≥ 2 kW
RL ≥ 1 kW
± 13.5 ± 14.0
V
± 12.5 ± 13.0
± 12.0 ± 12.5
SLEW RATE2
SR
RL ≥ 2 kW
0.1
0.3
V/ms
CLOSED-LOOP BANDWIDTH2
BW
AVCL = +1
0.4
0.6
MHz
OPEN-LOOP OUTPUT RESISTANCE RO
60
W
POWER CONSUMPTION
Pd
VS = ± 15 V, No Load
VS = ± 3 V, No Load
50
60
mW
3.5
4.5
OFFSET ADJUSTMENT RANGE
RP = 20 kW
±3
mV
NOTES
1Long-Term Input Offset Voltage Stability refers to the averaged trend line of V OS vs. Time over extended periods after the first 30 days of operation. Excluding the
initial hour of operation, changes in VOS during the first 30 operating days are typically 2.5 mV.
2Sample tested.
3Guaranteed by design.
–2–