Parameter
AC SPECIFICATIONS (continued)
High-to-Low Transition Time for DATACK (DHLT)
Clock to Data Skew, tSKEW3
Duty Cycle, DATACK, DATACK3
Conditions
Test
AD9887AKS
Temp Level Min Typ Max
Output Drive = High; CL =10 pF Full IV
1.4
Output Drive = Med; CL = 7 pF Full IV
1.6
Output Drive = Low; CL = 5 pF Full IV
2.4
Full IV 0
4.0
Full IV 45
55
DATACK Frequency (fCIP) (1 Pixel/Clock)
DATACK Frequency (fCIP) (2 Pixels/Clock)
NOTES
1The typical pattern contains a gray scale area, Output Drive = High.
2DATACK and DATACK Load = 10 pF, Data Load = 5 pF, HDCP disabled.
3Drive Strength = 11
Specifications subject to change without notice.
Full VI 20
140
Full IV 10
85
Unit
ns
ns
ns
ns
% of
Period
High
MHz
MHz
ABSOLUTE MAXIMUM RATINGS*
VD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.6 V
VDD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.6 V
Analog Inputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . VD to 0.0 V
VREF IN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . VD to 0.0 V
Digital Inputs . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 V to 0.0 V
Digital Output Current . . . . . . . . . . . . . . . . . . . . . . . . . 20 mA
Operating Temperature . . . . . . . . . . . . . . . . . . –25°C to +85°C
Storage Temperature . . . . . . . . . . . . . . . . . . –65°C to +150°C
Maximum Junction Temperature . . . . . . . . . . . . . . . . . 150°C
Maximum Case Temperature . . . . . . . . . . . . . . . . . . . . 150°C
*Stresses above those listed under Absolute Maximum Ratings may cause perma-
nent damage to the device. This is a stress rating only; functional operation of the
device at these or any other conditions outside of those indicated in the operation
sections of this specification is not implied. Exposure to absolute maximum ratings
for extended periods may affect device reliability.
Test
Level
I
II
III
IV
V
VI
EXPLANATION OF TEST LEVELS
Explanation
100% production tested.
100% production tested at 25°C and sample
tested at specified temperatures.
Sample tested only.
Parameter is guaranteed by design and charac-
terization testing.
Parameter is a typical value only.
100% production tested at 25°C; guaranteed
by design and characterization testing.
Model
AD9887AKS-170
AD9887AKS-140
AD9887AKS-100
AD9887A/PCB
ORDERING GUIDE
Max Speed (MHz)
Analog
DVI
170
170
140
140
100
100
Temperature
Range
0°C to 70°C
0°C to 70°C
0°C to 70°C
25°C
Package
Description
Metric Quad Flatpack
Metric Quad Flatpack
Metric Quad Flatpack
Evaluation Board
Package
Option
S-160
S-160
S-160
CAUTION
ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily
accumulate on the human body and test equipment and can discharge without detection. Although the
AD9887A features proprietary ESD protection circuitry, permanent damage may occur on devices
subjected to high energy electrostatic discharges. Therefore, proper ESD precautions are recommended
to avoid performance degradation or loss of functionality.
REV. 0
–7–