English
Language : 

OP07Z Datasheet, PDF (5/16 Pages) Analog Devices – Ultralow Offset Voltage Operational Amplifier
Data Sheet
OP07
Parameter
OUTPUT CHARACTERISTICS
TA = 25°C
Output Voltage Swing
−40°C ≤ TA ≤ +85°C
Output Voltage Swing
DYNAMIC PERFORMANCE
TA = 25°C
Slew Rate
Closed-Loop Bandwidth
Open-Loop Output Resistance
Power Consumption
Offset Adjustment Range
Symbol Conditions
VO
RL ≥ 10 kΩ
RL ≥ 2 kΩ
RL ≥ 1 kΩ
VO
RL ≥ 2 kΩ
SR
RL ≥ 2 kΩ3
BW
AVOL = 15
RO
VO = 0, IO = 0
Pd
VS = ±15 V, No load
VS = ±3 V, No load
RP = 20 kΩ
Min Typ Max Unit
±12.0 ±13.0
V
±11.5 ±12.8
V
±12.0
V
±12 ±12.6
V
0.1 0.3
V/μs
0.4 0.6
MHz
60
Ω
80
150 mW
4
8
mW
±4
mV
1 Input offset voltage measurements are performed by automated test equipment approximately 0.5 seconds after application of power.
2 Long-term input offset voltage stability refers to the averaged trend time of VOS vs. the time over extended periods after the first 30 days of operation. Excluding the
initial hour of operation, changes in VOS during the first 30 operating days are typically 2.5 μV. Refer to the Typical Performance Characteristics section. Parameter is
sample tested.
3 Sample tested.
4 Guaranteed by design.
5 Guaranteed but not tested.
Rev. G | Page 5 of 16