ADV612_15 Datasheet, PDF (40/46 Pages) Analog Devices – Closed Circuit TV Digital Video Codec
ADV611/ADV612
Host Interface (Indirect Address, Indirect Register Data and Interrupt Mask/Status) Register Timing
The diagrams in this section show transfer timing for host read and write accesses to all of the ADV611/ADV612’s direct registers,
except the Compressed Data register. Accesses to the Indirect Address, Indirect Register Data, and Interrupt Mask/Status registers
are slower than access timing for the Compressed Data register. For information on access timing for the Compressed Data direct
register, see the Host Interface (Compressed Data) Register Timing section. Note that for accesses to the Indirect Address, Indirect
Register Data and Interrupt Mask/Status registers, your system MUST observe ACK and RD or WR assertion timing.
Table XXVI. Host (Indirect Address, Indirect Data, and Interrupt Mask/Status) Read Timing Parameters
Parameter
Description
tRD_D_RDC
tRD_D_PWA
tRD_D_PWD
tADR_D_RDS
tADR_D_RDH
tDATA_D_RDD
tDATA_D_RDOH
tRD_D_WRT
tACK_D_RDD
tACK_D_RDOH
RD Signal, Direct Register, Read Cycle Time (at 27 MHz VCLK)
RD Signal, Direct Register, Pulsewidth Asserted (at 27 MHz VCLK)
RD Signal, Direct Register, Pulsewidth Deasserted (at 27 MHz VCLK)
ADR Bus, Direct Register, Read Setup
ADR Bus, Direct Register, Read Hold
DATA Bus, Direct Register, Read Delay
DATA Bus, Direct Register, Read Output Hold (at 27 MHz VCLK)
WR Signal, Direct Register, Read-to-Write Turnaround (at 27 MHz VCLK)
ACK Signal, Direct Register, Read Delayed (at 27 MHz VCLK)
ACK Signal, Direct Register, Read Output Hold (at 27 MHz VCLK)
NOTES
1RD input must be asserted (low) until ACK is asserted (low).
2Maximum tDATA_D_RDD varies with VCLK according to the formula: tDATA_D_RDD (MAX) = 4 (VCLK Period) +16.
3During STATS_R deasserted (low) conditions, tDATA_D_RDD may be as long as 52 VCLK periods.
4Minimum tRD_D_WRT varies with VCLK according to the formula: tRD_D_WRT (MIN) = 1.5 (VCLK Period) –4.1.
5Maximum tACK_D_RDD varies with VCLK according to formula: tACK_D_RDD (MAX) = 7 (VCLK Period) +14.8.
6During STATS_R deasserted (low) conditions, tACK_D_RDD may be as long as 52 VCLK periods.
Min
N/A1
N/A1
5
2
2
N/A
26
48.74
8.6
11
Max
N/A
N/A
N/A
N/A
N/A
171.62, 3
N/A
N/A
287.15, 6
N/A
Unit
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
(I) RD
(I) ADR, BE, CS
(O) DATA
tRD D PWA
VALID
tADR D RDS
tDATA D RDD
tRD D RDC
tRD D PWD
tADR D RDH
VALID
tDATA D RDOH
VALID
VALID
(I) WR
tRD D WRT
(O) ACK
tACK D RDD
tACK D RDOH
Figure 32. Host (Indirect Address, Indirect Register Data, and Interrupt Mask/Status) Read Transfer Timing
–40–
REV. 0