English
Language : 

ADT7318_15 Datasheet, PDF (30/44 Pages) Analog Devices – 0.5C Accurate Digital Temperature Sensor and Quad Voltage Output 12-/10-/8-Bit DACs
ADT7316/ADT7317/ADT7318
DAC D Register LSBs (Read/Write) [Address 0x16]
This 8-bit read/write register contains the 4/2 LSBs of the
ADT7316/ADT7317 DAC D word, respectively. The value in
this register is combined with the value in the DAC D register
MSBs and converted to an analog voltage on the VOUT-D pin.
On power-up, the voltage output on the VOUT-D pin is 0 V.
Table 31. DAC D (ADT7316) LSBs
D7 D6 D5 D4 D3 D2 D1 D0
B3 B2 B1 LSB N/A N/A N/A N/A
01
01
01
01
N/A N/A N/A N/A
1 Default settings at power-up.
Table 32. DAC D (ADT7317) LSBs
D7 D6 D5 D4 D3 D2 D1 D0
B1 LSB N/A N/A N/A N/A N/A N/A
01
01
N/A N/A N/A N/A N/A N/A
1 Default settings at power-up.
DAC D Register MSBs (Read/Write) [Address 0x17]
This 8-bit read/write register contains the 8 MSBs of the DAC D
word. The value in this register is combined with the value in
the DAC D register LSBs and converted to an analog voltage on
the VOUT-D pin. On power-up, the voltage output on the VOUT-D
pin is 0 V.
Table 33. DAC D MSBs
D7
D6 D5 D4 D3 D2 D1 D0
MSB B8 B7 B6 B5 B4 B3 B2
01
01
01
01
01
01
01
01
1 Default settings at power-up.
Control Configuration 1 Register (Read/Write)
[Address 0x18]
This configuration register is an 8-bit read/write register that
is used to setup some of the operating modes of the ADT7316/
ADT7317/ADT7318.
Table 34. Control Configuration 1
D7 D6 D5 D4 D3 D2 D1 D0
PD C6 C5 C4 C3 C2 C1 C0
01
01
01
01
01
01
01
01
1 Default settings at power-up.
Table 35. Control Configuration 1 Bit Descriptions
Bit Function
C0 This bit enables/disables conversions in round robin
mode and single-channel mode. The
ADT7316/ADT7317/ ADT7318 power up in round-robin
mode, but monitoring is not initiated until this bit is set.
0 = Stop monitoring (default).
1 = Start monitoring.
C1:4 Reserved. Only write 0s.
C5 0 = Enable INT/INT output. 1 = Disable INT/INT output.
C6 Configures INT/INT output polarity. 0 = Active low.
1 = Active high.
PD Power-Down Bit. Setting this bit to 1 puts the ADT7316/
ADT7317/ADT7318 into standby mode. In this mode,
both the ADC and the DACs are fully powered down, but
the serial interface is still operational. To power up the
part again, write 0 to this bit.
Control Configuration 2 Register (Read/Write)
[Address 0x19]
This configuration register is an 8-bit, read/write register that
is used to set up some of the operating modes of the ADT7316/
ADT7317/ADT7318.
Table 36. Control Configuration 2
D7 D6 D5 D4 D3 D2 D1 D0
C7 C6 C5 C4 C3 C2 C1 C0
01
01
01
01
01
01
01
01
1 Default settings at power-up.
Table 37. Control Configuration 2
Bit
Function
C0:1 In single-channel mode, these bits select between VDD,
the internal temperature sensor, and the external
temperature sensor for conversion.
00 = VDD (default).
01 = Internal temperature sensor.
10 = External temperature sensor.
11 = Reserved.
C2:3 Reserved.
C4
Selects between single-channel and round robin
conversion cycle. Default is round robin.
0 = Round robin.
1 = Single channel.
C5
Default condition is to average every measurement on
all channels 16 times. This bit disables this averaging.
Channels affected are temperature and VDD.
0 = Enable averaging.
1 = Disable averaging.
C6
SMBus timeout on the serial clock puts a 25 ms limit
on the pulse width of the clock. Ensures that a fault
on the master SCL does not lock up the SDA line.
SMBus timeout.
0 = Disable.
1 = Enable SMBus timeout.
C7
Software reset. Setting this bit to 1 causes a software
reset. All registers and DAC outputs reset to their
default settings.
Rev. B | Page 30 of 44