English
Language : 

ADUM1301ARWZ-RL Datasheet, PDF (21/32 Pages) Analog Devices – Triple-Channel Digital Isolators
Data Sheet
ADuM1300/ADuM1301
ABSOLUTE MAXIMUM RATINGS
Ambient temperature = 25°C, unless otherwise noted.
Table 13.
Parameter
Storage Temperature (TST)
Ambient Operating Temperature (TA)1
Ambient Operating Temperature (TA)2
Supply Voltages (VDD1, VDD2)3
Input Voltage (VIA, VIB, VIC, VE1, VE2)3, 4
Output Voltage (VOA, VOB, VOC)3, 4
Average Output Current per Pin5
Side 1 (IO1)
Side 2 (IO2)
Common-Mode Transients6
Rating
−65°C to +150°C
−40°C to +105°C
−40°C to +125°C
−0.5 V to +7.0 V
−0.5 V to VDDI + 0.5 V
−0.5 V to VDDO + 0.5 V
−23 mA to +23 mA
−30 mA to +30 mA
−100 kV/μs to +100 kV/μs
1 Does not apply to ADuM1300W and ADuM1301W automotive grade
versions.
2 Applies to ADuM1300W and ADuM1301W automotive grade versions.
3 All voltages are relative to their respective ground.
4 VDDI and VDDO refer to the supply voltages on the input and output sides of a
given channel, respectively. See the PC Board Layout section.
5 See Figure 3 for maximum rated current values for various temperatures.
6 This refers to common-mode transients across the insulation barrier.
Common-mode transients exceeding the Absolute Maximum Ratings may
cause latch-up or permanent damage.
Stresses above those listed under Absolute Maximum Ratings
may cause permanent damage to the device. This is a stress
rating only; functional operation of the device at these or any
other conditions above those indicated in the operational
section of this specification is not implied. Exposure to absolute
maximum rating conditions for extended periods may affect
device reliability.
ESD CAUTION
Table 14. Maximum Continuous Working Voltage1
Parameter
Max Unit
AC Voltage, Bipolar Waveform 565 V peak
AC Voltage, Unipolar Waveform
Basic Insulation
1131 V peak
Reinforced Insulation
560 V peak
DC Voltage
Basic Insulation
1131 V peak
Reinforced Insulation
560 V peak
Constraint
50-year minimum lifetime
Maximum approved working voltage per IEC 60950-1
Maximum approved working voltage per IEC 60950-1 and VDE V 0884-10
Maximum approved working voltage per IEC 60950-1
Maximum approved working voltage per IEC 60950-1 and VDE V 0884-10
1 Refers to continuous voltage magnitude imposed across the isolation barrier. See the Insulation Lifetime section for more details.
Table 15. Truth Table (Positive Logic)
VIx Input1 VEx Input1, 2 VDDI State1 VDDO State1
H
H or NC Powered Powered
L
H or NC Powered Powered
X
L
Powered Powered
X
H or NC Unpowered Powered
X
L
Unpowered Powered
X
X
Powered Unpowered
VOx Output1
H
L
Z
H
Z
Indeterminate
Notes
Outputs return to the input state within 1 μs of VDDI power restoration.
Outputs return to the input state within 1 μs of VDDO power restoration
if the VEx state is H or NC. Outputs return to a high impedance state
within 8 ns of VDDO power restoration if the VEx state is L.
1 VIx and VOx refer to the input and output signals of a given channel (A, B, or C). VEx refers to the output enable signal on the same side as the VOx outputs. VDDI and VDDO
refer to the supply voltages on the input and output sides of the given channel, respectively.
2 In noisy environments, connecting VEx to an external logic high or low is recommended.
Rev. I | Page 21 of 32