English
Language : 

ADUM1200UR-EP Datasheet, PDF (19/28 Pages) Analog Devices – Dual-Channel Digital Isolators
Data Sheet
ADuM1200/ADuM1201
PACKAGE CHARACTERISTICS
Table 8.
Parameter
Resistance (Input-to-Output)1
Capacitance (Input-to-Output)1
Input Capacitance
IC Junction-to-Case Thermal Resistance, Side 1
IC Junction-to-Case Thermal Resistance, Side 2
Symbol Min Typ Max Unit Test Conditions
RI-O
1012
Ω
CI-O
1.0
pF
f = 1 MHz
CI
4.0
pF
θJCI
46
°C/W Thermocouple located at
center of package underside
θJCO
41
°C/W
1 The device is considered a 2-terminal device; Pin 1, Pin, 2, Pin 3, and Pin 4 are shorted together, and Pin 5, Pin 6, Pin 7, and Pin 8 are shorted together.
REGULATORY INFORMATION
The ADuM1200/ADuM1201 and ADuM1200W/ADuM1201W are approved by the organizations listed in Table 9; refer to Table 14 and
the Insulation Lifetime section for details regarding recommended maximum working voltages for specific cross-isolation waveforms and
insulation levels.
Table 9.
UL
Recognized Under 1577 Component
Recognition Program1
Single/Basic 2500 V rms Isolation Voltage
File E214100
CSA
Approved under CSA Component Acceptance
Notice #5A; approval pending for ADuM1200W/
ADuM1201W automotive 125°C temperature grade
Basic insulation per CSA 60950-1-03 and
IEC 60950-1, 400 V rms (566 peak) maximum
working voltage
Functional insulation per CSA 60950-1-03 and
IEC 60950-1, 800 V rms (1131 V peak) maximum
working voltage
File 205078
VDE
Certified according to DIN V VDE V
0884-10 (VDE V 0884-10): 2006-122
Reinforced insulation, 560 V peak
File 2471900-4880-0001
1 In accordance with UL 1577, each ADuM120x is proof tested by applying an insulation test voltage ≥ 3000 V rms for 1 second (current leakage detection limit = 5 μA).
2 In accordance with DIN V VDE V 0884-10, each ADuM120x is proof tested by applying an insulation test voltage ≥ 1050 V peak for 1 sec (partial discharge detection
limit = 5 pC). The * marking branded on the component designates DIN V VDE V 0884-10 approval.
INSULATION AND SAFETY-RELATED SPECIFICATIONS
Table 10.
Parameter
Rated Dielectric Insulation Voltage
Minimum External Air Gap (Clearance)
Minimum External Tracking (Creepage)
Minimum Internal Gap (Internal Clearance)
Tracking Resistance (Comparative Tracking Index)
Isolation Group
Symbol
L(I01)
L(I02)
CTI
Value
2500
4.90 min
4.01 min
0.017 min
>175
IIIa
Unit
V rms
mm
mm
mm
V
Conditions
1 minute duration
Measured from input terminals to output terminals,
shortest distance through air
Measured from input terminals to output terminals,
shortest distance path along body
Insulation distance through insulation
DIN IEC 112/VDE 0303 Part 1
Material Group (DIN VDE 0110, 1/89, Table 1)
Rev. I | Page 19 of 28