5B02, STB-TCI, STB-HLI, STB-TC, STB-HL02, STB-AOT
FEATURES
A Variety of Solutions for Analog Signal Interfacing
Isolated and Nonisolated Signal Conditioning
Interfacing Capabilities to a Wide Variety of Real-World
Sensors Including:
Thermocouples
RTDs
OBSOLETE Strain Gages
Other Low Level Voltage Inputs
Current Inputs
High Level Voltage Inputs
Current Outputs
High Level Voltage Outputs
Panels Are Interchangeable Using Same Cables and
Addressing Scheme
I/O Modules or Screw Terminals Removable for Easy
Field Installation and Replacement
Modular Analog Expansion for RTI®-820
19" Rack Mountable
GENERAL DESCRIPTION
The Analog Devices family of multiplexed analog signal condi-
tioning panels offers a variety of ways to connect real-world
signals to data acquisition boards. The panels described in this
data sheet can all be used with the RTI-820, and any other
Interchangeability of the different panels is accomplished by use
of a standard multiplexed analog bus developed by Analog
Devices. This bus allows the high channel capacity possible for
the RTI-820. The multiplexed analog signals are brought to
the RTI-820 via the CAB-01 or CAB-01-2 cables.
product that supports the Analog Devices multiplexed analog
bus standard. These panels may be mixed and matched in an
application since they are addressed in the same fashion by the
RTI-820. Consult the appropriate RTI-820 data sheet to deter-
mine the maximum number of analog signal conditioning panels
supported.
For all panels, field signals are brought in via screw terminal
connectors. A screw terminal is also provided for the connection
of the +5 V power supply. Other voltages required for the ana-
log circuitry are produced on-board. The RTI products provide
+5 V power capability for some extra panels. The PWR-01
power supply is recommended for the panels and provide ample
5B Series signal conditioning modules are sealed for protection
from harsh environments. The optional CV-01 cover may be
used to protect each of the five STB panels.
The 5B02, STB-TCI and STB-HLI provide signal conditioning
for those applications requiring high electrical isolation. The
STB-TC, STB-AOT, and STB-HL02 panels provide nonisolated
signal conditioning. This data sheet gives the description and
specifications for each of these panels. In addition there is a
panel selection guide for quick reference, an I/O comparison
chart as a configuration aid and a mounting diagram at the end
of the data sheet.
+5 V power for most applications. Consult the RTI-820 data
sheet for more information about powering the panels.
RTI is a registered trademark of Analog Devices, Inc.
REV. A
Information furnished by Analog Devices is believed to be accurate and
reliable. However, no responsibility is assumed by Analog Devices for its
use, nor for any infringements of patents or other rights of third parties
which may result from its use. No license is granted by implication or
otherwise under any patent or patent rights of Analog Devices.
One Technology Way, P.O. Box 9106, Norwood, MA 02062-9106, U.S.A.
Tel: 781/329-4700 World Wide Web Site: http://www.analog.com
Fax: 781/326-8703
© Analog Devices, Inc., 1998