English
Language : 

ACE24LC02 Datasheet, PDF (6/17 Pages) ACE Technology Co., LTD. – Two-wire Serial EEPROM
Technology
ACE24(L)C02/04/08/16
Two-wire Serial EEPROM
ACE24LC02/04/08/16
Applicable over recommended operating range from: TA = -40℃ to +85℃, VCC = +1.7V to +3.6V, (unless otherwise noted).
Symbol
Parameter
Test Condition
Min Typ Max Units
VCC
Supply Voltage
1.7
3.6
V
ICC1
Supply Current
ICC2
Supply Current
VCC = 3.6V, Read at 100K
VCC = 3.6V, Write at 100K
0.4 1.0 mA
1.5 2.0 mA
ISB1
Standby Current
VCC = 1.7V, VIN = VCC/ VSS
1.0 µA
ISB2
Standby Current
VCC = 3.6V, VIN = VCC/ VSS
ILI
Input Leakage Current
VIN = VCC/VSS
3.0 µA
0.10 3.0 µA
ILO
Output Leakage Current
VOUT = VCC/ VSS
0.05 3.0 µA
VIL1
Input Low Level
-0.6
VCCx0.3 V
VIH1
Input High Level
VCCx0.7
5.5
V
VOL
Output Low Level
VCC = 2.7V, IOL = 2.1 mA
0.4
V
VOL1
VOL2
Output Low Level
Output Low Level
VCC = 3.0V, IOL = 2.1 mA
VCC = 1.8V, IOL = 0.15 mA
0.4
V
0.2
V
Note: 1. VIL min and VIH max are reference only and are not tested.
AC Characteristics
ACE24C02/04/08/16
Applicable over recommended operating range from: TA = -40℃ to +85℃, VCC = +2.5V to +5.5V, CL = 1 TTL Gate and 100
pF (unless otherwise noted). Test conditions are listed in Note 2.
Symbol
Parameter
2.2-volt 5.0-volt
Units
Min Max Min Max
fSCL
Clock Frequency, SCL
100
400 kHz
TLOW
THIGH
Clock Pulse Width Low
Clock Pulse Width High
4.7
1.2
µs
4.0
0.6
µs
TAA
Clock Low to Data Out Valid
0.1 4.5 0.1 0.9 µs
TBUF1
Time the bus must be free before a new transmission can
4.7
Start
1.2
µs
THD.STA Start Hold Time
4.0
0.6
µs
TSU.STA Start Setup Time
4.7
0.6
µs
THD.DAT
TSU.DAT
Data In Hold Time
Data In Setup Time
0
0
µs
200
100
ns
TR
Inputs Rise Time
1.0
0.3 µs
TF
Inputs Fall Time
300
300 ns
VER 1.3 6