English
Language : 

NL1022T Datasheet, PDF (1/3 Pages) List of Unclassifed Manufacturers – Thermoelectric Cooler
MECHANICAL CHARACTERISTICS
TECHNICAL DATA SHEET
NL1022T
Single-Stage Thermoelectric Module
RoHS EU Compliant
TYPICAL PERFORMANCE VALUES
Hot Side Temperature (°C)
∆ Tmax (°C-dry N2):
Qmax (watts):
Imax (amps):
Vmax (vdc):
AC Resistance (ohms):
Device ZT
27°C
64
4.0
1.8
3.5
1.70
0.77
50°C
73
4.6
1.8
4.0
--
--
-01, -02, -03, -04
-05AC
*NOTE: Cold side, Hot Side, and positive and negative leads are valid only for thermoelectric cooling. For power generation, refer to page 3.
ORDERING OPTIONS
Model Number
NL1022T-01
NL1022T-02
NL1022T-03
NL1022T-04
NL1022T-05AC
Description
Both Surfaces are Metallized, Buss Wires
Hot Side Exterior is Metallized, Buss Wires
No Metallization, Buss Wires
No Metallization, RTV Sealed, Buss Wires
No Metallization, RTV Sealed, Insulated Wires,
Alumina Only
AVAILABLE MODIFICATIONS
 Pretinned metallized ceramic surface(s) with 117°C solder.
 Thermistor mounted on edge of cold side ceramic.
(Calibration available.)
 Elevated temperature burn-in with test data provided.
For customer support or general questions please contact a local office or visit our website at www.marlow.com