English
Language : 

NL1013T Datasheet, PDF (1/4 Pages) List of Unclassifed Manufacturers – Thermoelectric Cooler
TECHNICAL DATA SHEET
MECHANICAL CHARACTERISTICS
.518
[13.16]
.518
[13.16]
NL1013T
Single-Stage Thermoelectric Module
RoHS EU Compliant
TYPICAL PERFORMANCE VALUES
Hot Side Temperature (°C)
∆ Tmax (°C-dry Vac):
Qmax (watts):
Imax (amps):
Vmax (vdc):
AC Resistance (ohms):
Device ZT
27°C
61
4.8
1.0
8.5
7.42
0.77
50°C
69
5.4
1.0
9.6
--
--
(+) *
Leads: 28 AWG, Buss,
Solid Tinned Copper
(-) *
2.00 +/-.25
[50.80+/-6.35]
.095+/-.005
[2.41 +/-0.13]
Cold Side, Tc *
* Hot Side, Th
Ceramic Material: Alumina (AC)
Millimeters are in [ ]
.005 [0.13] A
.001 [0.03]
.001 [0.03]
A
-01AC, -02AC, -03AC
*NOTE: Cold side, hot side, positive leads, and negative leads are valid only for thermoelectric cooling. For
power generation, refer to page 4.
ORDERING OPTIONS
PRODUCT FEATURES
Model Number
NL1013T-01AC
NL1013T-02AC
NL1013T-03AC
NL1013T-04AC
Description
TEM, Top and Base Metallized Exterior
TEM, Base Metallized Exterior
TEM, No Metallized Exterior
TEM, No Metallized Exterior, Sealed,
Special Wires
 Maximum operating temperature is 85°C.
 Maximum process temperature is 220°C.
 Ceramic Material: Aluminum Oxide
 Metallized Exterior Surfaces are Au flash, suitable for
soldering.
 RTV Sealing options available.
For customer support or general questions please contact a local office or visit our website at www.marlow.com.
DOC # 102-0292 REV J - PAGE 1 OF 4