English
Language : 

RL0601D Datasheet, PDF (1/4 Pages) ULTRA LEVEL TECH CO., LTD. – AC-DC SWITCHING POWER SUPPLY
ULTRA LEVEL TECH CO., LTD.
www.ultralevel.com.tw Tel:+886-2-29180118 Fax:+886-2-29181465
We Supply the Power Customers Need ISO9001
125W ~ 300W AC-DC SWITCHING POWER SUPPLY
RL0601D DUAL OUTPUT SERIES
FEATURES:
◆ Compact 300W with 1U height Power Density: 8.3 watts/cu in
◆ Low Leakage Current 500uA @ 240Vac / 300uA @ 120Vac
◆ 5/ 12/ 24/ 48V Dual Output Optional Combinations
◆ Power Factor Corrected to EN61000-3-2 class A
◆ Variable Fan Speed & Low Acoustical Noise
◆ High Quality & Reliable Component Usage
◆ Approved to UL CUL TUV CB and CE
◆ AC Input Range Auto-Selectable
E Type: 7(L) x 4(W) x 1.6(H) inches.
◆ 4 - Mechanical Options
U Type: 6(L) x 4(W) x 1.5(H) inches.
PRODUCT SPECIFICATIONS:
C Type: 6(L) x 4(W) x 1.55(H) inches.
F Type: 6(L) x 4(W) x 2(H)inches.
CB
Input Voltage: 90-132 / 180-264Vac auto-ranging, 47~63Hz.
Input Current: 8/4A at 100-120/200-240Vac.
Inrush Current: Max. 70A@230Vac & 35A@115Vac; cold start.
PFC: Power Factor Correction pass EN61000-3-2 class A.
Transient Response: Returns to within 1% in less than 2.5mS for a
50% load change and the peak transient does not excess 5%.
Overshoot: Turn-on & off overshoot < 5% over nominal voltage.
Efficiency: 75% ~ 85% depends on model.
Turn On Delay: 1 second maximum at 230 Vac.
Hold Up Time: 20mS min. at 80% of full load.
Adjustability: Output user adjustable +/-5% minimum.
Fan Drive: 12VDC/400mA offering to drive an external fan.
Fan Fail (FF) Alarm: Designated as FF on pin 3 of CN1, two types
of logical signal provided, contact manufacturer.
Power Supply On: Green LED designated as LED1 on the PCB.
Power Good: PG on CN1 goes high 100-500mS after DC regulation
and low at least 1mS before loss of regulation (Open collector).
Input Fusing Protection: One T8A/250V fuse inserted in primary.
Over-Power Protection: 110~140% of I-Max; Auto-recovery.
Short Circuit Protection: Trip without damage and auto-recovery.
Over Voltage Protection: Unit latching down when output exceed
130% and recycle AC input to reset.
Over-Temperature Protection: Unit protected of excessive
operating ambient 110 ℃, and automatic recovery.
Switching Frequency: 23K Hz fixed frequency.
Operating Temperature: 0℃ to 70℃ ambient, de-rating at 2.5% per
degree from 50℃ to 70℃.
Storage Temperature: -20 to 85 ℃.
Storage Humidity: 5% to 95% RH, Non-condensing.
Operating Humidity: 5% to 90% RH, Non-condensing.
Vibration: 5 ~ 50 Hz, acceleration 7.35 m/s*s on X,Y and Z Axis.
EMC: EN55022 class B conducted / radiated, EN61000-3-2,
EN61000-3-3; EN55024 (IEC61000-4-2, IEC61000-4-3, IEC61000-
4-4, IEC61000-4-5, IEC61000-4-6, IEC61000-4-11).
Safety Regulation: UL60950-1, EN60950-1, IEC60950-1.
Leakage Current: < 1mA @ 264Vac.
(optional for 500uA max. at 240Vac / 300uA max. at 120Vac input)
HI-POT Test: 1500 VAC input line to chassis (10mA DC cut off
current); Isolating 3000VAC primary to secondary windings;
Primary to core 1500VAC. All for 3 sec.
Grounding Test: Apply 25 A from ground pin of the three prong
plug to the far most earth. Max allowable resistance 0.1 ohm.
Warranty: 2 years.
MTBF: 100000 Hrs (according to MIL-HBK-217F) at 30 ℃ .
Cooling:
U Type: U-Chassis @300W max. with 18CFM airflow or 150W max.
convection cooling
C Type: U-Chassis with top cover @150W max. convection cooling
E Type: Enclosed with side built-in fan @300W max.
F Type: Enclosed with top built-in fan @300W max.
Burn in: 45 +/- 5 degree C for 1 hour @230Vac with full load.
Enclosure:
U Type: 6(L) x 4(W) x 1.5(H) inches.
C Type: 6(L) x 4(W) x 1.55(H) inches.
E Type: 7(L) x 4(W) x 1.6(H) inches.
F Type: 6(L) x 4(W) x 2(H)inches.
Weight: Maximum weight is 800g.
Copy Right Ultra Level Tech Co., Ltd 2015, All Right Reserved. Specifications subject to change without notice.