English
Language : 

GC-120 Datasheet, PDF (1/2 Pages) Total Power International – 120W Single Output Battery Charger
120W Single Output Battery Charger
GC120 series
■  
‧   
‧     
‧    
‧   
‧    
‧      
‧          
‧    
‧   
‧      
‧         
‧  
ORDER NO.
OUTPUT CONNECTOR
GC120Axx-R7B (standard model)
4pin power din
GC120Axx-AD1 (optional model)
Anderson connector
GC120Axx- xx=12,24,48 ; =R7B,AD1
      
SAFETY
TUV / CB / FCC / CE
UL / TUV / CB / FCC / CE
SPECI FIC AT ION
ORDER NO.
GC120A12-
GC120A24-
GC120A48-
OUTPUT
SAFETY MODEL NO.
GC120A12
DC VOLTAGE (Typ.)
13.6V
RECOMMENDED BATTERY
40 ~ 100Ah
CAPACITY
Note.2
CONTINUOS OUTPUT
CURRENT (Typ.)
7.5A
GC120A24
27.2V
20 ~ 65Ah
4.42A
GC120A48
54.4V
10 ~ 35Ah
2.21A
RATED POWER
102W
120.2W
120.2W
LED INDICATOR
Charging(CC) : RED Floating charging(CV) : GREEN
VOLTAGE RANGE Note.3 85 ~ 264VAC 120 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF>0.97 / 230VAC PF>0.99 / 115VAC at full load
INPUT EFFICIENCY (Typ.)
86.5%
90%
91%
AC CURRENT
1.4A / 115VAC 0.7A / 230VAC
INRUSH CURRENT (max.) 70A / 230VAC
LEAKAGE CURRENT(max.) 0.75mA / 240VAC
OV E RLO A D
90 ~ 110% rated output power
Note .4
Protection type : Constant current limitin g recovers automatically after fault con dition is removed
SHORT CIRCUIT
PROTECTION
OVER VOLTAGE
Protection type : Hiccup mode, recovers automatica lly after fau lt condition is removed
14 ~ 16.5V
29 ~ 33V
59 ~ 69V
Protection type : Shut d own o /p voltage, re-power on to recover
OVER TEMPERATURE
1 00℃±10℃ (RTH2) de tect o n inside ambient temperature
Protection type : Shut d own o /p voltage, re-power on to recover
WORKING TEMP.
WORKING HUMIDITY
-30 ~ +70℃ (Refer to "Derating Curve")
20% ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85℃, 10 ~ 95% RH
TEMP. COEFFICIENT
±0.03% / ℃ (0~50℃)
VIBR ATIO N
SAFETY STANDARDS
SAFETY & WITHSTAND VOLTAGE
EMC
ISOLATION RESISTANCE
(Note. 5) EMC EMISSION
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL1012 (for GC120Axx-AD1 only), TUV EN60950-1 approved
I/P-O/P: 3KVAC
I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH
Compliance to EN55022 class B, FCC PART 15 class B / CISPR22 class B, EN61000-3-2,3
EMC IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A
MTBF
400.7K hrs min. MIL-HDBK-217F(25℃)
OTHERS DIMENSION
PACKING
PLUG
CON NE CTO R
CABLE
167*67*35mm (L*W*H)
0.62Kg; 20pcs/13.4Kg/0.9CUFT
See page 2 ; Other type available by customer requested
See page 2 ; Other type available by customer requested
NOTE
              ℃   
                  
                
          
                         
 
F ile Na me:GC120 -SPEC 2011-08- 09