English
Language : 

E2KC25MF1 Datasheet, PDF (5/8 Pages) Omron Electronics LLC – Adjustable Capacitive Prox
E2K-C
E2K-C
Residual Load Voltage Characteristics
DC switching types
E2K-C25M ❑ ❑
AC switching types
E2K-C25MY ❑
24VDC
100 VAC
200 VAC
1
ON (V2)
0.5
24 VDC
0.1
0.05
OFF (V1)
0.01
0
50 100 150 200 250
Load current (mA)
R <=
VS
10 –
i
(kΩ)
P> VS2 (mW)
R
P : Power rating of bleeder resistor
i : Load current (mA)
VS : Supply voltage (V)
Residual
100
output
voltage
90
80
70
60
50
40
30
ON
Load
AC
100V
20 Residual
10
load
voltage
0
1
5
OFF
10
50 100 200
Load current (mA)
Residual
output
voltage
200
ON
150
100
Load
50 Residual
load
voltage
0
1
5
AC
200V
OFF
10
50 100 200
Load current (mA)
Note: When the current rating of the load is less than 10 mA, false operation may
occur. This is normal, and the problem can be cured by installing a bleeder resistor in
parallel with the load. Use the formulas given here to calculate the power rating and
value of the resistor.
Leakage Current Characteristics
AC switching types
E2K-C25MY ❑
3.0
2.5
2.0
1.5
1.0
0.5
OFF state
0
0 80 100 120 140 160 180 200 220 240
260
Supply voltage (V)
Dimensions
Unit: mm (inch)
s SENSORS
E2K-C25M ❑ ❑
34 (1.34)
dia.
20
(0.79)
82
(3.23)
31
(1.22)
0.15
(0.006)
Note: Cable may be extended to 200 m (656 ft).
Cap screw for
sensitivity adjustment
6
(0.24)
Operation indicator
(LED)
Cable: 2 m (6.56 ft.) length
6