RKP-1U_12 Datasheet, PDF (1/6 Pages) Mean Well Enterprises Co., Ltd. – RKP-1U_12
2000~6000W Front End Power System R K P - 1 U R a c k S y s t e m
Features :
Universal AC input / Full range
Holds up to 3 power modules
Active current sharing up to 6000W(3 unit) in one 19”rack, 3 rack max.
can be operated in parallel (up to 9 units)
PMBus serial interface
IEC320-C20 or terminal block input
Front-end & rectifier applications
Stackable for system expansion
Low profile: 1U height, 19” rack mount
Hot swappable modules
Output voltage trimming function
3 years warranty
Description :
RCP-2000 rack power system is an advanced 19” rack-mounted power system containing up to 3 hot-swappable RCP-2000 rectifiers and
can deliver up to 6000W in the single rack. Up to 3 racks can be stacked to provide expanded total system capability up to 18,000W that
are especially suitable for the application of servers, information technology equipment, networking, telecommunications, and wide
range of industrial applications using distributed power architecture. Equipped with PMBus communication protocol, RCP-2000 rack
system can be controlled or monitored by external device such as monitoring unit (RCP-CMU-1) or PC.
SELECTION GUIDE
Rack: RKP-1U I - CMU1
CMU1: With RKP-CMU1
-: Without RKP-CMU1
Whole System: RKP-6K1U I - CMU1 - 12
I: AC Inlet (IEC320-C20)
T: Terminal block
Output voltage
CMU1: With RKP-CMU1
-: Without RKP-CMU1
I: AC Inlet (IEC320-C20)
T: Terminal block
SPECIFICATION - Rack System
MODEL
RKP-6K1U -12
RKP-6K1U -24
RKP-6K1U -48
MODULE
RCP-2000-12
RCP-2000-24
RCP-2000-48
RACK
RKP-1UI or RKP-1UT
OUTPUT OUTPUT VOLTAGE
12V
24V
48V
MAX. OUTPUT CURRENT 300A
240A
126A
MAX. OUTPUT POWER Note.6 3600W
5760W
6048W
VOLTAGE RANGE
Note.5 90 ~ 264VAC 127 ~ 370VDC
INPUT
FREQUENCY RANGE
47 ~ 63Hz
AC CURRENT (Typ.)FOR EACH UNIT 13A/115VAC
7A/230VAC
16A/115VAC 11A/230VAC
16A/115VAC 11A/230VAC
LEAKAGE CURRENT
<3.5mA / 230VAC
AUXILIARY POWER
5V @ 0.3A, 12V @ 0.8A
REMOTE ON/OFF CONTROL By electrical signal or dry contact ON:short OFF:open
FUNCTION
REMOTE SENSE
DC OK SIGNAL
AC FAIL SIGNAL
Compensate voltage drop on the load wiring up to 0.5V. "Local Sense"should be connected in order to get the correct output voltage if the "Remote Sense"is not used
The isolated TTL signal out, refer to function manual
The isolated TTL signal out, refer to function manual
OUTPUT VOLTAGE TRIM
Adjustment of output voltage, possible between 90 ~ 110% of rated output
OVER TEMP WARNING
Logic " High" for over temperature warning, refer to function manual, isolated signal
FAN FAIL SIGNAL
The isolated TTL signal out, refer to function manual
WORKING TEMP.
-40 ~ +70 (Refer to "Derating Curve")
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
20 ~ 90% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH
0.03%/ (0 ~ 50 )
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY STANDARDS
UL60950-1, TUV EN60950-1 approved
SAFETY & WITHSTAND VOLTAGE
EMC
ISOLATION RESISTANCE
(Note 4) EMC EMISSION
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.7KVDC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 (CISPR22) Conduction Class B, Radiation Class A ; EN61000-3-2,-3
EMC IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61000-6-2 (EN50082-2), heavy industry level, criteria A
OTHERS
NOTE
DIMENSION
Rack 483.6*350.8*44(L*W*H)
PACKING
11.5Kg; 1pcs/11.5Kg/2.67CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
5. Derating may be needed under low input voltages. Please check the static characteristics for more details.
6. Output of all the RCP-2000 modules are connected in parallel in the rack.
7. Under parallel operation of more than one rack connecting together, ripple of the output voltage may be higher than the SPEC at light load condition.
It will go back to normal ripple level once the output load is more than 10%.
File Name:RKP-1U RACK SYSTEM-SPEC 2012-03-12