English
Language : 

LPV-100 Datasheet, PDF (1/2 Pages) Mean Well Enterprises Co., Ltd. – 100W Single Output Switching Power Supply
100W Single Output Switching Power Supply
LPV-100 series
Features :
Constant voltage design
Universal AC input / Full range
Fully encapsulated with IP67 level (Note.8)
Withstand 300VAC surge input for 5 seconds
Protections: Short circuit / Overload / Over voltage
Fully isolated plastic case
Cooling by free air convection
100% full load burn-in test
Low cost, high reliability
Suitable for LED lighting and moving sign applications(Note 7.)
SPECIFICATION
2 years warranty
IP67
MODEL
LPV-100-5
LPV-100-12
LPV-100-15
LPV-100-24
LPV-100-36
LPV-100-48
DC VOLTAGE
5V
12V
15V
24V
36V
48V
RATED CURRENT
12A
8.5A
6.7A
4.2A
2.8A
2.1A
CURRENT RANGE
0 ~ 12A
0 ~ 8.5A
0 ~ 6.7A
0 ~ 4.2A
0 ~ 2.8A
0 ~ 2.1A
RATED POWER
60W
102W
100.5W
100.8W
100.8W
100.8W
OUTPUT
RIPPLE & NOISE (max.) Note.2 80mVp-p
VOLTAGE TOLERANCE Note.3 8.0%
LINE REGULATION
1.0%
120mVp-p
5.0%
120mVp-p
150mVp-p
150mVp-p
150mVp-p
LOAD REGULATION
6.0%
2.0%
SETUP, RISE TIME Note.6 2000ms, 25ms / 230VAC 2000ms, 25ms / 115VAC
HOLD UP TIME (Typ.)
50ms/230VAC 14ms/115VAC at full load
VOLTAGE RANGE Note.4 90 ~ 264VAC 127 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
EFFICIENCY (Typ.)
80%
85%
87%
88%
88%
89%
INPUT
AC CURRENT
2.2A/115VAC 1.2A/230VAC
INRUSH CURRENT(max.) COLD START 30A/115VAC 75A/230VAC
LEAKAGE CURRENT
0.25mA / 240VAC
OVER CURRENT
PROTECTION
OVER VOLTAGE
110 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
5.75 ~ 6.75V
13.8 ~ 16.2V
17.25 ~ 20.25V
27.6 ~ 32.4V
Protection type : Shut down o/p voltage, re-power on to recover
41.4 ~ 48.6V
55.2 ~ 64.8V
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
-25 ~ +70 (Refer to output load derating curve)
20 ~ 90% RH non-condensing
-40 ~ +80 , 10 ~ 95% RH
0.03%/ (0 ~ 50 )
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY STANDARDS
IP67 approved; Design refer to TUV EN60950-1, EN61347-2-13
SAFETY &
EMC
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION
HARMONIC CURRENT
EMS IMMUNITY
MTBF
I/P-O/P:3KVAC
I/P-O/P:>100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 (CISPR22) Class B
Compliance to EN61000-3-2 Class A( 80% load), EN61000-3-3
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, heavy industry level, criteria A
703Khrs min. MIL-HDBK-217F (25 )
OTHERS
NOTE
DIMENSION
190*52*37mm (L*W*H)
PACKING
0.63Kg;20pcs/13.6Kg/0.57CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltage. Please check the static characteristics for more details.
5. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
7. In the European market this product is only suitable for LED lighting applications that don t have to comply with the harmonic current requirements of
EN61000-3-2 Class C.
8. Suitable for indoor use or outdoor use without direct sunlight exposure.
File Name:LPV-100-SPEC 2011-03-09