English
Language : 

408-4098 Datasheet, PDF (3/5 Pages) Tyco Electronics – Pnuematic Platform Adapters
Pneumatic Platform Adapters 679992- 1 and 679992- 2
408- 4098
2. Insert platform adapter into tool holder as shown
in Figure 1.
3. After platform adapter is properly aligned, insert
and tighten quick pins provided with the tool holder
assembly (refer to Figure 1).
NOTE
i
We recommend using LOCTITE{ 242 removable
threadlock, or equivalent, to prevent the quick
pins from loosening..
4. Connect pneumatic tool to an adequate air
supply between 620 and 690 kPa [90 and100 psi].
For specific information on air line requirements
and air hose installation, refer to the instructions
packaged with the pneumatic tooling assembly.
B. Removal
DANGER To avoid personal injury, ALWAYS disconnect tool
from air supply before removing platform adapter.
Remove quick pins from platform adapter; then
remove platform adapter from tool holder.
4. CRIMPING PROCEDURE (Figure 4)
Strip the wire to the appropriate length according to
Application Specification 114--2123. Proceed as
follows:
CAUTION
!
Do NOT operate the tool without the platform
adapter or die assembly properly installed.
DANGER
To avoid personal injury or damage to the tool,
always keep fingers clear of jaws, and frequently
check the quick pins to ensure that they are
secure.
1. The locator stop must be adjusted to
accommodate the terminal series size, which is
marked on the terminal insulation (.110, .187,
or .250). Rotate the blue plastic locator stop until
the series size matches the terminal series size.
NOTE
i
If crimping a flag terminal, the locator stop does
NOT need to be adjusted.
2. Open the dies by squeezing the adapter rollers
together.
3. Center the terminal wire barrel in the appropriate
crimping chamber on the lower die.
a. For straight terminals, insert mating end into
crimping chamber with the flat side facing the
locator assembly (for Adapter --1) as shown in
Figure 4, or the upper die (for Adapter --2). Allow
terminal to butt against the locator stop.
b. For flag terminals, orient the terminal as
shown in Figure 4. The mating end must be
seated on the locator assembly (for Adapter --1),
or the upper die (for Adapter --2).
4. After terminal is properly positioned, release the
adapter rollers to allow the dies to spring shut,
holding the terminal in place.
5. Insert stripped wire into wire barrel until the wire
bottoms.
Strip Length
(Ref)
Lower Die
Ultra- Fast FASTON
Terminals (Ref)
{ Trademark of Loctite Corporation
Rev D
Series Size Marking
(Must Match Terminal
Series Size)
Locator
Assembly
(Ref)
Figure 4
Upper Die
Locator
Stop
Tyco Electronics Corporation
3 of 5