English
Language : 

LAL0660-50 Datasheet, PDF (1/1 Pages) LinkCom Manufacturing Co., Ltd. – Broadband Access Transformer
LAL0660-50
Broadband Access Transformer
Designed to meet UL 60950 and EN 60950 requirements for supplementary insulation and
250V working voltage
RoHS Compliant
Excellent THD performance
Operating Temperature -40°C to 85°C
OCL:
Leakage
Inductance:
IInterwinding
Capacitance
T.H.D
D.C.R
Hi-POT :
Turn Ratio:
Electrical Specifications @25℃
PIN 16-9= 700uH ±6% @ 10KHz/0.1V/Ser.
PIN 1-4= 1.2uH ±0.2 @ 100KHz/0.1V
PIN 5-8= 4.0uH ±1.0
PIN 16-9= 15uH ±2.0
PIN 1-16= 20 pF ±5.0 @ 100KHz/0.1V
PIN 5-16= 20 pF ±5.0
PIN 1-8= 15 pF ±3.0
PIN 1-4 to PIN 9-16= -90dB Max. @ 100KHz/7.5V
PIN 5-8 to PIN 9-16= -90dB Max. @ 100KHz/7.5V
PIN 1-4 = 1.15 ohm ±15%
PIN 5-8 = 2.0 ohm ±15%
PIN 16-9 = 4.1 ohm ±15%
PRI. – SEC. =1875VAC/60Hz/2Seconds/1mA
PIN16-9 : PIN 1-4 = 4±3% :1
PIN16-9 : PIN 5-8 = 2±3% :1
Dimensions (Units: mm)
F
3.4±0.3
1.00
5.1±0.3
G
LAL****
LinkCom B
X DATE CODE G
13.5±0.5
A
PIN1
11.90
SUGGESTED PADS LAYOUT
C
1.7±0.3
E
0.5TYP.
12.5REF.
15.6±0.5
D
Schematic
1
Tx
3
2
4
5
Rx
7
6
8
SEC
PRI
16
11
LINE
14
9
Mark
1.LAL****----LAL0660
2. X----PRODUCT LINE
3. DATE CODE----YYWW
4. G----RoHS
Form Ver. A