English
Language : 

LAL0286-51 Datasheet, PDF (1/1 Pages) LinkCom Manufacturing Co., Ltd. – Broadband Access Transformer
LAL0286-51
Broadband Access Transformer
Designed to meet UL 60950 and EN 60950 requirements for supplementary insulation and
250V working voltage
RoHS Compliant
Excellent THD performance
Operating Temperature -40°C to 85°C
OCL:
Leakage
Inductance:
T.H.D
D.C.R:
Hi-POT :
Turn Ratio:
Electrical Specifications @25℃
PIN 1-5= 100uH ±5% @ 10KHz/0.1V/Ser.
PIN 1-5= 4.5uH ±1.0 @ 300KHz/0.1V
PIN 1-5 to PIN 10-6 = -80dB Max. @ 30KHz/3.162V
PIN 1-4 = 420 mohm ±15%
PIN 2-5 = 420 mohm ±15%
PIN 9-6 = 245 mohm ±15%
PIN 10-7 = 185 mohm ±15%
PRI. – SEC. =1875VAC/60Hz/2Seconds/1mA
PIN1-5 : PIN 10-6 = 2±2% :1
Dimensions (Units: mm)
0.7TYP.
1.80
LAL****
LinkCom H
X Date Code G
13.4±0.5
G
A
12.6±0.5
PIN1
2.5
PIN1
SUGGESTED PAD LAYOUT
C
13.5±0.5
B
2.5REF
I
D
13.0±0.5
E
15.5±0.5
F
17.0 +1.0
-0.5
Schematic
10
9
6
Mark
1.LAL****----LAL0286
2. X----PRODUCT LINE
3. DATE CODE----YYWW
4. G----RoHS
Form Ver. A