LB100-S Datasheet, PDF (1/2 Pages) LEM – Current Transducer LB 100-S/SP3
Current Transducer LB 100-S/SP3
For the electronic measurement of currents : DC, AC, pulsed...,
with a galvanic isolation between the primary circuit (high power)
and the secondary circuit (electronic circuit).
IPN = 100 A
Electrical data
IPN
Primary nominal r.m.s. current
IP
Primary current, measuring range
R M Measuring resistance
with ± 15 V
@ ± 100 A max
@ ± 200 A max
ISN
Secondary nominal r.m.s. current
K N Conversion ratio
VC
Supply voltage (± 5 %)
IC
Current consumption
Vd
R.m.s. voltage for AC isolation test, 50 Hz, 1 mn
Accuracy - Dynamic performance data
X
Accuracy @ IPN, TA = 25°C
e
L
Linearity
IO
IOT
tr
di/dt
f
Offset current @ IP = 0, TA = 25°C
Thermal drift of IO
+ 10°C .. + 50°C
Response time 2) @ 90 % of IPN
di/dt accurately followed
Frequency bandwidth (- 1 dB)
Zero crossing distortion
General data
TA
Ambient operating temperature
TS
Ambient storage temperature
R S Secondary coil resistance @ TA = 50°C
m
Mass
Standards 3)
100
A
0 .. ± 200
A
RM min
RM max
0
85
W
0
30
W
100
mA
1 : 1000
± 15
V
20 + IS
mA
5 1)
kV
± 0.5
%
< 0.1
%
Typ Max
± 0.4 mA
± 0.35 ± 0.4 mA
<1
> 50
DC .. 150
negligeable
µs
A/µs
kHz
+ 10 .. + 50 °C
- 25 .. + 85 °C
25
W
180
g
EN 50178
Features
· Closed loop (compensated) current
transducer using the Hall effect
· Insulated plastic case recognized
according to UL 94-V0.
Special features
· VC = ± 15 (± 5 %) V
· Better zero crossing performance
· TA = + 10°C .. + 50°C
· Potted.
Advantages
· Excellent accuracy
· Very good linearity
· Low temperature drift
· Optimized response time
· Wide frequency bandwidth
· No insertion losses
· High immunity to external
interference
· Current overload capability.
Applications
· AC variable speed drives and servo
motor drives
· Static converters for DC motor drives
· Battery supplied applications
· Uninterruptible Power Supplies (UPS)
· Switched Mode Power Supplies
(SMPS)
· Power supplies for welding
applications
· HVDC transmisions.
Notes : 1) Between primary and secondary.
2) With a di/dt of 100 A/µs
3) A list of corresponding tests is available.