English
Language : 

LAH100-P_06 Datasheet, PDF (1/2 Pages) LEM – Current Transducer
Current Transducer LAH 100-P
For the electronic measurement of currents : DC, AC, pulsed ...,
with a galvanic isolation between the primary circuit
(high power) and the secondary circuit (electronic circuit).
IPN = 100 A
Electrical data
16052
I
Primary nominal r.m.s. current
PN
IP
Primary current, measuring range 1)
R
Measuring resistance @
M
100
A
0 .. 160
A
T = 70°C T = 85°C
A
A
R R R R M min M max M min M max
with ± 12 V
@ IPN [± A DC ]
0 63 0 57 Ω
@ IPN [A RMS ] 2)
0 11 0 5 Ω
with ± 15 V
@ IPN [± A DC ]
20 120 45 114 Ω
@ I [A ] 2)
PN RMS
20 51 45 45 Ω
@ IP
<
I 3)
PN
I
Secondary nominal r.m.s. current
SN
50
mA
K N Conversion ratio
1 : 2000
V
Supply voltage (± 5 %)
C
± 12 .. 15
V
IC
Current consumption
10 (@ ± 15 V)+I mA
S
V
R.m.s. voltage for AC isolation test, 50/60 Hz, 1 mn 5
kV
d
Ve
R.m.s. voltage for partial discharge extinction @ 10 pC > 2
kV
V
Impulse withstand voltage 1.2/50 µs
w
> 12
kV
Accuracy - Dynamic performance data
X
Accuracy 4) @ I T = 25°C
εL
PN, A
Linearity error
± 0.25
%
< 0.15
%
Typ Max
I
Offset current @ T = 25°C
O
A
± 0.15 mA
IOM Residual current @ IP = 0, after an overload of 5 x IPN ± 0.10 ± 0.15 mA
I
Thermal drift of I
OT
O
0°C .. + 70°C ± 0.10 ± 0.40 mA
- 25°C .. + 85°C ± 0.10 ± 0.50 mA
tr a
t
r
di/dt
f
Reaction time @ 10 % of IPN
Response time 5) @ 90 % of I
PN
di/dt accurately followed
Frequency bandwidth (- 1 dB)
< 200
< 500
> 200
DC .. 200
ns
ns
A/µs
kHz
General data
T
Ambient operating temperature
A
TS
Ambient storage temperature
R
Secondary coil resistance
S
Insulating material group
m
Mass
Standards
@ T = 70°C
A
@ TA = 85°C
- 25 .. + 85
°C
- 40 .. + 90
°C
115
Ω
121
Ω
I
24
g
EN 50178 : 1997
Features
• Closed loop (compensated) current
transducer using the Hall effect
• Printed circuit board mounting
• Insulated plastic case recognized
according to UL 94-V0.
Advantages
• Excellent accuracy
• Very good linearity
• Low temperature drift
• Optimized response time
• Wide frequency bandwidth
• No insertion losses
• High immunity to external
interference
• Current overload capability.
Applications
• AC variable speed drives and servo
motor drives
• Static converters for DC motor drives
• Battery supplied applications
• Uninterruptible Power Supplies
(UPS)
• Switched Mode Power Supplies
(SMPS)
• Power supplies for welding
applications.
Notes : 1) For 10 s, with RM ≤ 25 Ω (VC = ± 15 V) - 2) 50 Hz Sinusoidal -
3) The measuring resistance RM min may be lower (see "LAH Technical
Information" leaflet) - 4) Without IO & IOM - 5) With a di/dt of 100 A/µs.
LEM
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.
060303/8
page 1/2