LAH100-P Datasheet, PDF (1/2 Pages) LEM – Current Transducer LAH 100-P
Current Transducer LAH 100-P
For the electronic measurement of currents : DC, AC, pulsed ...,
with a galvanic isolation between the primary circuit
(high power) and the secondary circuit (electronic circuit).
IPN = 100 A
Electrical data
IPN
Primary nominal r.m.s. current
IP
Primary current, measuring range 1)
RM Measuring resistance @
100
A
0 .. 160
A
TA = 70°C TA = 85°C
RM min RM max RM min RM max
with ± 12 V
@ IPN [± A DC ]
0 63 0 57 Ω
@ IPN [A RMS ] 2)
0 11 0 5 Ω
with ± 15 V
@ IPN [± A DC ]
20 120 45 114 Ω
@ IPN [A RMS ] 2)
20 51 45 45 Ω
@ IP < IPN 3)
ISN Secondary nominal r.m.s. current
50
mA
KN Conversion ratio
1 : 2000
VC Supply voltage (± 5 %)
± 12 .. 15
V
IC
Current consumption
10 (@ ± 15 V)+I m A
S
Vd
R.m.s. voltage for AC isolation test, 50/60 Hz, 1 mn 5
kV
Ve
R.m.s. voltage for partial discharge extinction @ 10 pC > 2
kV
Vw Impulse withstand voltage 1.2/50 µs
> 12
kV
Accuracy - Dynamic performance data
X
εL
Accuracy4) @ IPN, TA = 25°C
Linearity
± 0.25
%
< 0.15
%
Typ Max
IO
Offset current @ TA = 25°C
± 0.15 m A
IOM Residual current @ IP = 0, after an overload of 5 x IPN ± 0.10 ± 0.15 m A
IOT
Thermal drift of IO
0°C .. + 70°C ± 0.10 ± 0.40 m A
- 25°C .. + 85°C ± 0.10 ± 0.50 m A
tr a
tr
di/dt
f
Reaction time @ 10 % of IPN
Response time 5) @ 90 % of IPN
di/dt accurately followed
Frequency bandwidth (- 1 dB)
General data
< 200
< 500
> 200
DC .. 200
ns
ns
A/µ s
kHz
TA
Ambient operating temperature
TS
Ambient storage temperature
RS Secondary coil resistance
Insulating material group
m Mass
Standards 6)
- 25 .. + 85
°C
- 40 .. + 90
°C
@ TA = 70°C 115
Ω
@ TA = 85°C 121
Ω
I
24
g
EN 50178
Notes : 1) For 10 s, with R M ≤ 25 Ω (VC = ± 15 V) - 2) 50 Hz Sinusoidal -
3) The measuring resistance RM min may be lower (see "LAH Technical
Information" leaflet) - 4) Without IO & IOM - 5) With a di/dt of 100 A/µs
6) A list of corresponding tests is available.
Features
• Closed loop (compensated) current
transducer using the Hall effect
• Printed circuit board mounting
• Insulated plastic case recognized
according to UL 94-V0.
Advantages
• Excellent accuracy
• Very good linearity
• Low temperature drift
• Optimized response time
• Wide frequency bandwidth
• No insertion losses
• High immunity to external
interference
• Current overload capability.
Applications
• AC variable speed drives and servo
motor drives
• Static converters for DC motor drives
• Battery supplied applications
• Uninterruptible Power Supplies
(UPS)
• Switched Mode Power Supplies
(SMPS)
• Power supplies for welding
applications.
010820/5
LEM Components
w w w.lem.com