English
Language : 

LPX200 Datasheet, PDF (1/2 Pages) Emerson Network Power – LPX200
Embedded Power for
Business-Critical Continuity
LPX200
Enclosure
Installation Notes
LPX200 • Cover Enclosure Kit
LPX200 will fit the LPX20X-M power supplies.
OUTPUT CONNECTOR
Rev. 12.9.09_153
LPX200 Enclosure
1 of 2
INPUT CONNECTOR
Materials
• 1 Base
• 1 Cover
• 4 M3x6mm Pan head
screws with spring washer
• 4 M3x6mm countersunk
screws
• 1 M4 nut
• 1 M4 star washer
• 1 M4 spring washer
• 1 Plastic insulator sheet
INSULATOR
GROUND STUD
(4X)STANDOFF
Installation Instructions and Notes
1. Place the insulator over the chassis as shown.
2. Place the power supply over the insulator as shown.
3. Align the power supply to the chassis standoff.
4. Secure 4 pan head screws with washer provided with in kit as shown.
5. Place the cover over the power supply as shown.
6. Align the cover to the U-bracket countersink holes.
7. Secure 4 countersink screws provided with in kit as shown.
8. Overall dimensions: 5.9” (150mm) x 3.85” (98mm) x 1.85” (46.9mm).
9. Base plate has three sets of customer mountings:
a. Bottom mounting (4X) M3 inserts. Max. screw penetration 0.0787 (2mm)plus 2 key
ways. (See keyway detail)
b. Side mounting (4X) M3 inserts. Max. screw penetration 0.236 (6mm)
10. Ensure insulator is correctly fitted in base under PCB to maintain safety creepage
and clearances.
11. Ensure base is firmly connected to supply earth via the earth stud marked
12. When using this enclosure, ensure that relevant safety standards (e.g. EN60950) are complied
with, in respect to creepage and clearance distances, and distances through insulation.
13. All dimensions are in inches (mm)