LPQ202-M Datasheet, PDF (1/3 Pages) Emerson Network Power – LPQ200-M Series 200 Watts
Embedded Power for
Business-Critical Continuity
LPQ200-M Series
200 Watts
Total Power:
Input Voltage:
# of Outputs:
100 - 200 Watts
90 - 264 Vac
Quad
Rev. 01.14.12_#43
LPQ200-M Series
1 of 3
Special Features
• Medical and ITE safeties
• Active power factor correction
• 3” x 5” footprint
• Less than 1U high
• EN61000-3-2 compliant
• Remote sense
• Power fail
• Adjustable outputs
• Built-in Class B EMI filter
• Overvoltage protection
• Overload protection
• Thermal overload protection
• LPX200 enclosure kit available
Safety
• TUV
• UL
• CSA
• CB
• CE
60950, 60601-1
60950, 60601-1
60950, 60601-1
Certificate & report
Mark (LVD)
Electrical Specifications
Input
Input ra­nge:
Frequency:
Inrush current:
Efficiency:
EMI/RFI:
Safety ground
leakage current:
90 - 264 Vac; 120 - 300 Vdc
47 - 63 Hz
50 A max., cold start @ 25 °C, 230 Vac input
84% typical at full load
FCC Class B conducted; CISPR22 Class B conducted;
EN55022 Class B conducted; VDE0878PT3 Class B conducted
275 uA @ 50/60 Hz, 264 Vac input
Output
Maximum power:
100 W for convection ; 200 W with 30CFM forced air
Adjustment range:
All outputs -20%, +10%, except for the 3.3 V output which will be -15%,
+10% (LPQ201-M)
Hold-up time:
16 ms @ 200 W load, 120 Vac input
Overload protection: Short circuit protection on all outputs. V1, V2 & V3 overload protected @
110 - 160%. V4 is 150 - 250% above rating
Overvoltage protection: 30 - 50% above nominal output on V1 (and V2 on LPQ202)
Logical Control
Power failure:
Remote sense:
Active low logic signal goes high 100-500 msec after main output; it goes
low at least 6 msec before loss of regulation
Compensates for 0.5 V lead drop min. Will operate without remote sense
connected. Reverse connection protected.