LPQ142 Datasheet, PDF (1/3 Pages) Astec America, Inc – 145 Watts | |||
|
Embedded Power for
Business-Critical Continuity
LPQ142 Series
145 Watts
Total Power:
Input Voltage:
# of Outputs:
110 - 145 Watts
85-264 VAC
120-300 VDC
Quad
Rev. 11.17.08_103
LPQ142 Series
of 3
Special Features
⢠Active power factor correction
⢠IEC EN61000-3-2 compliance
⢠Adjustable outputs on 1, 3 & 4
Remote sense on main output
⢠Single wire current sharing
⢠Power fail and remote inhibit
⢠Built-in EMI filter
⢠Low output ripple
⢠Overvoltage protection
⢠Overload protection
⢠Thermal overload protection
⢠Adjustable floating 4th output
⢠Optional cover (-C suffix)
⢠Optional fan cover (-CF suffix)
Safety
⢠VDE
⢠UL
⢠CB
⢠CSA
⢠CE
⢠NEMKO
60950
60950
Certificate and report
60950
Mark (LVD)
EN 60950/EMKO-TUE
Electrical Specifications
Input
Input raÂnge:
Frequency:
Inrush current:
Efficiency:
EMI filter:
Power Factor:
Safety ground
leakage current:
Output
Maximum power:
Adjustment range:
Hold-up time:
Overload protection:
Overvoltage protection:
85-264 VAC; 120-300 VDC
47-67 Hz
38 A max, cold start @ 25°C
75% typical at full load
Meets FCC Class B conducted
CISPR 22 Class B conducted
EN55022 Class B conducted
VDE 0878 PT3 Class B conducted
0.99 typical
1.0 mA @ 50/60 Hz, 264 VAC input
80 W convection (60 W with cover -C)
145 W with 30 CFM forced air
(100 W with cover -C)
3.3 - 5.5V on main; -12 - 15V on 3rd output
3.3 - 25 V on 4th output
20 ms @175 W load at nominal line
Short circuit protection on all outputs. Case overload protected @
110-145% above peak rating
Tracks outputs 1, 3 & 4; 10 to 35%
|
▷ |