Absolute Maximum Ratings*
Tolerance
Inches
Metric
Min
Max Min
Max
A
-
1.20 -
30.50
B
-
0.41 -
10.40
C 0.345
0.375 8.76
9.53
D 0.125
0.140 3.18
3.56
E
0.016 typ.
0.41 typ.
F 0.021
0.031 0.53
0.79
G
0.10 ref.
2.5 ref.
H
0.10 typ.
2.5 ref.
I
0.985
1.015 25.02
25.78
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at conditions
beyond those indicated in the operational sections of this
data sheet is not implied.
Specifications
Parameter
Dual Coils
Pick Up Current
Drop Out Current
Coil Current
Coil Resistance
Coil Inductance
Longitudinal Balance
Excitation to Closure Time
(Including Bounce)
Excitation Removal to Open Time
Relay Contact
Voltage Rating
Current Rating
Power (Resistive) Rating
Rated Life
Dielectric Strength Open Contacts
Coil to Coil
Coil to Contact
Ambient
Operating
Temperature
Non-operating
Notes:
1. With coils in series-aiding configuration.
2. With the current continuously applied.
3. At 1 kHz.
4. With current of 20-100mA at 200-3000 kHz.
5. With current of 20mA and coils series-aiding configuration.
6. At 10W (resistive.)
7. Maximum initial contact resistance ≤ 1.0ohms.
Conditions
0o to 70oC ambient
0o to 70oC ambient
20oC ambient
-
-
-
-
-
-
-
-
-
-
-
-
85% RH
95% RH
Min
18
-
-
-
-
63
-
-
200
500
10
107
300
1000
1500
0
-20
Max
Units Notes
-
mA
1
6
mA
1
125
mA
2
20
ohms
-
4
mH
3
-
dB
4
1
ms
5
0.5
ms
-
-
VDC
-
-
mA
-
-
W
-
-
operations 6
-
VDC
-
-
VDC
-
-
VDC
-
70
ºC
-
70
ºC
-
2
www.clare.com