English
Language : 

LPS63-M Datasheet, PDF (1/2 Pages) Astec America, Inc – 60 Watts, Medical
60 Watts
LPS60 Series
Medical
Total Power: 60-80 Watts
Input Voltage: 85-264 VAC
120-300 VDC
# of Outputs: Single
Electrical Specs
Special Features
• Medical safety approvals
• Universal input
• 3” x 5” footprint
• Remote sense
• Built-in EMI filter
• Low output ripple
• Adjustable output
• Overvoltage protection
• Overload protection
• 110 KHz switching frequency
• LPX60 enclosure kit available
Environmental
Input
Input range
Frequency
Inrush current
Input current
Efficiency
EMI filter
Safety ground leakage
current
Output
Maximum power
Adjustment range
Hold-up time
Overload protection
Overvoltage protection
Remote sense
85-264 VAC
120-300 VDC
47-440 Hz
<18 A peak @ 115 VAC;
<36 A peak @ 230 VAC,
cold start @ 25°C
1.5 A max. (RMS) @ 115 VAC
70% typical at full load
FCC Class A conducted
CISPR 22 Class A conducted
EN55022 class A conducted
VDE 0878 PT3 class A conducted
<75 µA @ 50/60 Hz, 264 VAC input
60 W for convection;
80 W with 30 CFM forced air
-5, +10% minimum
20 ms @ 60 W load, 115 VAC nominal line
Short circuit protection on all outputs.
Case overload protected @ 110-145%
above peak rating
5 V output: 5.7-6.7 VDC. Other outputs
10% to 25% above nominal output
Compensates for 0.5 V lead drop min. Will
operate without remote sense connected.
Reverse connection protected.
Operating temperature: 0° to 50°C ambient
derate each output at 2.5% per degree from 50° to
70°C
Electromagnetic susceptibility: designed to meet
IEC 801, -2, -3, -4, -5, -6, Level 3
Humidity: Operating; non-condensing
5% to 95%
Vibration: Three orthogonal axes, sweep at 1
oct/min, 5 min. dwell at four major resonances
0.75 G peak 5 Hz to 500 Hz, operational
Storage temperature: -40° to 85°C
Temperature coefficient: ±.04% per °C
MTBF demonstrated: >550,000 hours at full load
and 25°C ambient conditions
Safety
VDE 0750/EN60601-1 (IEC601)
UL
UL2601
CSA CSA 22.2 No. 601.1
CE
Mark (LVD)
21310-3336-0015
E182560
LR109492
rev 08.11.04
Technical Support: (888) 41-ASTEC or (407) 241-2752
94
Americas: (760) 930-4600
Europe (UK) 44 (1384) 842-211
Asia (HK) 852-2437-9662