LPT51-M Datasheet, PDF (1/3 Pages) Artesyn Technologies – Total Power: 47 - 55 Watts | |||
|
POWER
Data Sheet
LPT50-M Series
55 Watts
Total Power: 47 - 55 Watts
Input Voltage: 90 - 264 Vac
127 - 300 Vdc
# of Outputs: Triple
SPECIAL FEATURES
ÂÂ Medical safety approvals
ÂÂ Universal input
ÂÂ 2â x 4â footprint
ÂÂ Less than 1U high
ÂÂ Overpower and short circuit protection
ÂÂ High efficiency
ÂÂ High MTBF
ÂÂ Built in EMI filter (CISPR 22 Class B)
ÂÂ LED power good indicator
ÂÂ Input power < 74 watts
ÂÂ Complies with EN61000 -3-2
ÂÂ 85 kHz switching frequency
ÂÂ Dual AC fuses
ÂÂ UL Class I approved
ÂÂ LPX100 enclosure kit available
ÂÂ RoHS compliant
SAFETY
ÂÂ UL:
ÂÂ CSA:
ÂÂ VDE:
ÂÂ CE:
UL 60601-1
CSA-C22.2 No. 601.1-M90
EN60601-1
LVD
Electrical Specifications
Input
Input range
90 - 264 Vac (wide range) 127 - 300 Vdc
Frequency
47 - 440 Hz
Inrush current
< 60 A peak @ 230 Vac, cold start @ 25 °C
Efficiency
80% typical at full load
EMI/RFI
FCC Class B conducted; CISPR 22 Class B conducted;
EN55022 Class B conducted, EN60601-1-2
Safety ground leakage current 275 μA @ 50/60 Hz; 264 Vac input
Output
Maximum power
55 W for convection (LPT51, 47.4 W)
Hold-up time
10/20 ms 115/230 Vac input line
Overpower protection
Short circuit protection on all outputs.
Case overpower protected @ 110-160% of normal rating
Overvoltage protection
30-50% above nominal output
Environmental Specifications
Operating temperature
0 °C to 50 °C ambient. Derate each output as 2.5% per degree
from 50 °C to 70 °C. -20 °C startup
Storage temperature
-40 °C to +85 °C
Electromagnetic susceptibility Designed to meet EN61000-4; -2, -3, -4, -5, -6, -8, -11 Level 3
Humidity
Operating; non-condensing 10% to 95% RH
Vibration
IEC68-2-6 to the levels of IEC721-3-2
MTBF demonstrated
> 550,000 hours at full load and 25 °C ambient conditions
|
▷ |