LPT41 Datasheet, PDF (1/4 Pages) Artesyn Technologies – Total Power: 44 - 55 Watts | |||
|
POWER
Data Sheet
Total Power: 44 - 55 Watts
Input Voltage: 85 - 264 Vac
120 - 300 Vdc
# of Outputs: Triple
SPECIAL FEATURES
ÂÂ Universal input
ÂÂ 3â x 5â footprint
ÂÂ Less than 1U high
ÂÂ Remote sense on main output
ÂÂ Built-in EMI filter
ÂÂ Low output ripple
ÂÂ Adjustable main output
ÂÂ Overvoltage protection
ÂÂ Overload protection
ÂÂ 110 KHz switching frequency
ÂÂ LPX40 enclosure kit available
ÂÂ RoHS compliant
SAFETY
ÂÂ UL
UL60950
E132002
ÂÂ cUL
60950
Level 3 LR53982C
ÂÂ NEMKO EN 60950/EMKO-TUE
P95100411 (74-sec) 203
ÂÂ CB
Certificate and report
1118, 1122, 1123, 1124
ÂÂ CE
Mark (LVD)
LPT40 Series
40 Watts
Electrical Specifications
Input
Input range
85 - 264 Vac; 120 - 300 Vdc
Frequency
47 - 440 Hz
Inrush current
< 18 A peak @ 115 Vac;
< 36 A peak @ 230 Vac, cold start @ 25 °C
Input current
1 A max. (RMS) @ 115 Vac
Efficiency
70% typical at full load (60% for LPT41)
EMI
FCC Class B conducted; CISPR 22 Class B conducted
EN55022 Class B conducted; VDE 0878 PT3 Class B conducted
Safety ground leakage current < 0.5 mA @ 50/60 Hz, 264 Vac input
Output
Maximum power
40 W for convection (LPT41, 25 W);
55 W with 30CFM forced air (LPT41, 41 W)
Cross regulation
±2% on output 1; ±5% on outputs 2, 3
Adjustment range
-5, +10% minimum
Hold-up time
20 ms @ 40 W load, 115 Vac nominal line
Overload protection
Short circuit protection on all outputs. Case overload protected
@ 110% to 145% above peak rating
Overvoltage protection
5.7 to 6.7 Vdc on the main outputLPT41: 3.6 to 4.6 Vdc
Remote sense
Compensates for 0.5 V lead drop min. Will operate without
remote sense connected. Reverse connection protected.
|
▷ |