LPS250 Datasheet, PDF (1/3 Pages) Astec America, Inc – 250 Watts | |||
|
POWER
Data Sheet
LPS250 Series
250 Watts
Total Power: 250 Watts
Input Voltage: 85 - 264 Vac
120 - 300 Vdc
# of Outputs: Single
SPECIAL FEATURES
ÂÂ Active power factor correction
ÂÂ IEC EN6100-3-2 compliance
ÂÂ Remote sense & remote inhibit
ÂÂ Power fail
ÂÂ Single wire current sharing
ÂÂ Built-in EMI filter
ÂÂ 2:1 Wide range output voltage adjust
ÂÂ 2 Supervisory outputs 5 V and 12 V
ÂÂ Overvoltage protection
ÂÂ Overload protection
ÂÂ Thermal overload protection
ÂÂ DC power good
ÂÂ 120 kHz switching frequency
ÂÂ RoHS compliant
ÂÂ Cover -C
ÂÂ Optional top with fan cover -CF
ÂÂ Optional end fan cover -CEF
SAFETY
ÂÂ VDE 60950
ÂÂ UL
60950
ÂÂ CSA 60950
ÂÂ NEMKO 60950
ÂÂ CB
Certificate and report 2186
ÂÂ CE
Mark (LVD)
Electrical Specifications
Input
Input range
85 - 264 Vac; 120 - 300 Vdc
Frequency
47 - 440 Hz
Inrush current
20 A max, cold start @ 25 °C
Efficiency
75% typical at full load
EMI filter
FCC Class B conducted and radiated
CISPR 22 Class B conducted and radiated
EN55022 Class B conducted and radiated
VDE 0878 PT3 Class B conducted and radiated
Safety ground leakage current < 0.5 mA @ 50/60 Hz, 264 Vac input
Output
Maximum power
With cover: 250 W with 30 CFM forced air.
(-C) (-CF) (CEF)
Supervisory output
5 V @ 100 mA regulated; 12 V @ 500 mA
Adjustment range
2:1 wide ratio
Hold-up time
20 ms @ 250 W load, 115 VAC nominal line
Overload protection
Short circuit protection on all outputs. Case overload protected @
10 - 145% above peak rating
Overvoltage protection
5 V output: 5.7 to 6.7 Vdc.
Other models 10% to 25% above nominal output
Logical Control
Power failure
TTL Logic signal goes high 50 - 150 msec after 5 V output. It goes low at
least 4 ms before loss of regulation
Remote on/off
Requires an external contact (N.O or N.C) to inhibit outputs
DC - OK
TTL logic goes high 50 - 150 msec after the output. It goes low when there
is loss of regulation.
Remote sense
Compensates for 0.5 V lead drop minimum, will operate without remote
sense connected. Reverse connection protected
|
▷ |