English
Language : 

LPQ201-M Datasheet, PDF (1/3 Pages) Artesyn Technologies – Total Power: 100 - 200 Watts
POWER
Data Sheet
Total Power: 100 - 200 Watts
Input Voltage: 90 - 264 Vac
# of Outputs: Quad
SPECIAL FEATURES
ƒƒ Medical and ITE safeties
ƒƒ Active power factor correction
ƒƒ 3” x 5” footprint
ƒƒ Less than 1U high
ƒƒ EN61000-3-2 compliant
ƒƒ Remote sense
ƒƒ Power fail
ƒƒ Adjustable outputs
ƒƒ Built-in Class B EMI filter
ƒƒ Overvoltage protection
ƒƒ Overload protection
ƒƒ Thermal overload protection
ƒƒ LPX200 enclosure kit available
ƒƒ RoHS compliant
SAFETY
ƒƒ TUV
ƒƒ UL
ƒƒ CSA
ƒƒ CB
ƒƒ CE
60950, 60601-1
60950, 60601-1
60950, 60601-1
Certificate & report
Mark (LVD)
LPQ200-M Series
200 Watts
Electrical Specifications
Input
Input ra­nge
90 - 264 Vac; 120 - 300 Vdc
Frequency
47 - 63 Hz
Inrush current
50 A max., cold start @ 25 °C, 230 Vac input
Efficiency
84% typical at full load
EMI/RFI
FCC Class B conducted; CISPR22 Class B conducted;
EN55022 Class B conducted; VDE0878PT3 Class B conducted
Safety ground
leakage current
275 μA @ 50/60 Hz, 264 Vac input
Output
Maximum power
100 W for convection; 200 W with 30CFM forced air
Adjustment range
All outputs -20%, +10%, except for the 3.3 V output which will be
-15%, +10% (LPQ201-M)
Hold-up time
16 ms @ 200 W load, 120 Vac input
Overload protection
Short circuit protection on all outputs. V1, V2 & V3 overload protected
@ 110 - 160%. V4 is 150 - 250% above rating
Overvoltage protection 30 - 50% above nominal output on V1 (and V2 on LPQ201-M)
Logical Control
Power failure
Active low logic signal goes high 100-500 msec after main output; it
goes low at least 6 msec before loss of regulation
Remote sense
Compensates for 0.4 V lead drop min. Will operate without remote
sense connected. Reverse connection protected.